Discrete I/O number: 16
-
Maximum number of I/O expansion module: 7 (local I/O-Architecture), 14 (remote I/O-Architecture)
-
Supply voltage limits: 20.4…28.8 V
-
Inrush current: 35 A
-
Maximum power consumption in W: 22.5 W at 24 V (with max number of I/O expansion module), 3.6 W at 24 V (without I/O expansion module)
-
Power supply output current: 0.52 A 5 V for expansion bus, 0.46 A 24 V for expansion bus
-
Discrete input logic: Sink or source (positive/negative)
-
Discrete input voltage: 24 V
-
Discrete input voltage type: DC
-
Analogue input resolution: 10 bits
-
LSB value: 10 mV
-
Conversion time: 1 ms per channel + 1 controller cycle time for analogue input analog input
-
Permitted overload on inputs: +/- 30 V DC for 5 min (maximum) for analog input, +/- 13 V DC (permanent) for analog input
-
Voltage state 1 guaranteed: >= 15 V for input
-
Voltage state 0 guaranteed: <= 5 V for input
-
Discrete input current: 7 mA for discrete input, 5 mA for fast input
-
Input impedance: 100 kOhm for analog input, 3.4 kOhm for input, 4.9 kOhm for fast input
-
Response time:
-
35 µs turn-off, I2...I5 terminal(s) for input
-
10 ms turn-on for output
-
10 ms turn-off for output
-
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
-
35 µs turn-on, other terminals terminal(s) for input
-
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
-
100 µs turn-off, other terminals terminal(s) for input
-
Configurable filtering time: 0 ms for input, 3 ms for input, 12 ms for input
-
Output voltage limits: 125 V DC, 277 V AC
-
Maximum current per output common: 7 A
-
Absolute accuracy error: +/- 1 % of full scale for analog input
-
Electrical durability:
-
100000 cycles AC-12, 120 V, 240 VA, resistive
-
100000 cycles AC-12, 240 V, 480 VA, resistive
-
300000 cycles AC-12, 120 V, 80 VA, resistive
-
300000 cycles AC-12, 240 V, 160 VA, resistive
-
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
-
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
-
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
-
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
-
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
-
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
-
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
-
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
-
100000 cycles DC-12, 24 V, 48 W, resistive
-
300000 cycles DC-12, 24 V, 16 W, resistive
-
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
-
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
-
Switching frequency: 20 switching operations/minute with maximum load
-
Mechanical durability: 20000000 cycles for relay output
-
Minimum load: 1 mA at 5 V DC for relay output
-
Protection type: Without protection at 5 A
-
Reset time: 1 s
-
Memory capacity: 256 kB for user application and data RAM with 10000 instructions, 256 kB for internal variables RAM
-
Data backed up: 256 kB built-in flash memory for backup of application and data
-
Data storage equipment: 2 GB SD card (optional)
-
Battery type: BR2032 lithium non-rechargeable, battery life: 4 year(s)
-
Backup time: 1 year at 25 °C (by interruption of power supply)
-
Execution time for 1 KInstruction: 0.3 ms for event and periodic task, 0.7 ms for other instruction
-
Execution time per instruction: 0.2 µs Boolean
-
Exct time for event task: 60 µs response time
-
Application structure: 8 interrupt tasks, 1 cyclic auxiliary task, 1 configurable freewheeling/cyclic master task
-
Maximum size of object areas: 8000 %MW memory words, 255 %TM timers, 255 %C counters, 512 %KW constant words, 512 %M memory bits
-
Realtime clock: With
-
Clock drift: <= 30 s/month at 25 °C
-
Regulation loop: Adjustable PID regulator up to 14 simultaneous loops
-
Counting input number: 4 fast input (HSC mode) at 100 kHz 32 bits
-
counter function: A/B, Pulse/direction, Single phase
-
Integrated connection type: USB port with mini B USB 2.0 connector, Non isolated serial link serial 1 with RJ45 connector and RS485 interface, Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
-
Supply: (Serial 1)serial link supply: 5 V, <200 mA
-
Transmission rate: 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485, 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232, 480 Mbit/s for USB
-
Communication port protocol: USB port: USB - SoMachine-Network, Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
-
Communication service: Modbus slave, Modbus master
-
Local signalling:
-
1 LED (green) for PWR
-
1 LED (green) for RUN
-
1 LED (red) for module error (ERR)
-
1 LED (green) for SD card access (SD)
-
1 LED (red) for BAT
-
1 LED (green) for SL1
-
1 LED (green) for SL2
-
1 LED per channel (green) for I/O state
-
Electrical connection:
-
Terminal block, 3 terminal(s) for connecting the 24 V DC power supply
-
Connector, 4 terminal(s) for analogue inputs
-
Mini B USB 2.0 connector for a programming terminal
-
Removable spring terminal block, 10 terminal(s) for inputs
-
Removable spring terminal block, 11 terminal(s) for outputs
-
Maximum cable distance between devices:
-
Shielded cable: <10 m for fast input
-
Unshielded cable: <30 m for output
-
Unshielded cable: <30 m for digital input
-
Unshielded cable: <1 m for analog input
-
Insulation:
-
Between input and internal logic at 500 V AC
-
Between fast input and internal logic at 500 V AC
-
Non-insulated between inputs
-
Between output and internal logic at 500 V AC
-
Between output groups at 500 V AC
-
Non-insulated between analogue input and internal logic
-
Non-insulated between analogue inputs
-
Marking: CE
-
Mounting support: Top hat type TH35-15 rail conforming to IEC 60715, Top hat type TH35-7.5 rail conforming to IEC 60715, Plate or panel with fixing kit
-
Height: 90 mm
-
Depth: 70 mm
-
Width: 70 mm
-
Product weight: 0.264 kg