KHK53-PXF00107 | SICK Sensors | Magnetic Linear encoders KH53 | Part Number : 1036164
KHK53-PXF00107 | SICK Sensors | Magnetic Linear encoders KH53 | Part Number : 1036164

KHK53-PXF00107 | SICK Sensors | Magnetic Linear encoders KH53 | Part Number : 1036164

0 Review(s)
USD7,686.00
Retail Price:USD8,839.00
Your Savings:USD1,153.00(13%)
Availability: Estimated Lead Time : 6 - 8 weeks.
Part Number: KHK53-PXF00107
Manufacturer:SICK Sensors
Condition : Brand New
Warranty : 12 monthsĀ 
Write a Review

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com.All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

NII REF No : IAFD112311071124

  • Estimated Lead Time : 6 - 8 weeks.

  • Manufacturer : SICK Sensors

  • Part Number : KHK53-PXF00107

  • MTTFD (mean time to dangerous failure) : 35 years (EN ISO 13849)

  • Measuring range : 0 m ... 107 m

  • Resolution : 0.1 mm

  • Traversing speed : 6.6 m/s

  • Repeatability : 0.3 mm

  • Measurement accuracy : ± 1000 + ME (Tu-25 °C) Tk µm

  • Communication interface : PROFIBUS DP

  • Bus interface : RS-485, according to EN 50 170-2 (DIN 19245 Parts 1–3) electrically isolated by optocoupler

  • Position forming time : + 1.1 ms

  • Address setting : 0 ... 127, Hex switches or Protocol

  • Data protocol : PROFIBUS DP basic functions (DP-V0)

  • Bus termination : Via external switches

  • Set (electronic adjustment) : Via protocol

  • Encoder profile : Profile for encoders (07hex) – Class 2

  • Data transmission rate (baud rate) : 9.6 kBaud ... 12 MBaud, Automatic detection

  • Status information : Operation (green LED) | Bus activity (red LED)

  • Initialization time : 2 s

  • Supply voltage : 10 V ... 32 V

  • Current consumption : 2.5 W

  • Connection type : Male connector, 3x, M12

  • MTTFd: mean time to dangerous failure : 35 years (EN ISO 13849)

  • Length of measuring element : See calculation example

  • Position tolerance : ± 10 mm, see positional tolerances diagram

  • Read head material : AlMgSiPbF28

  • Weight : 2.7 kg 

  • Shipping Weight : 4 kg

Reward Points

7686 points will be rewarded to you when you buy this item.