Estimated Lead Time : 6 - 8 Weeks
Manufacturer : SICK Sensors
Part Number : DL100-23AA2102
Supply voltage Vs : DC 18 V ... 30 V, limit values
Ripple : 5 Vpp 1)
Initialization time : Typ. 1.5 s 2)
Housing material : Metal (Aluminum die cast)
Window material : Plastic (PMMA)
Connection type : Male connector, M12, SPEEDCON⢠compatible
Indication : 6 digit 5 x 7 dot matrix display, LEDs
Weight : Approx. 800 g (with mounting bracket: approx. 1,600 g)
Current consumption : At 24 V DC < 250 mA
Modulation frequency : Fix
Enclosure rating : IP65
Protection class : III
1) May not fall short of or exceed VS tolerances.
2) After loss of reflector < 40 ms.
3) Without mounting bracket : approx. 800 g, with mounting bracket : approx. 1,600 g.
Measuring range : 1.05 m ... 200 m, on reflective tape "Diamond Grade"
Target : Reflector
Resolution : 1.0 mm, 1.025 mm, 1 mm, 10 mm, 100 mm
Repeatability : 1 mm 1)
Accuracy : ± 2.5 mm 2)
Response time : 2 ms
Measurement cycle time : 1 ms
Output time : 1 ms
Light source : Laser, red 3)
Laser class : 2, complies with 21 CFR 1041.00 and 1041.01 except for the tolerance according to āLaser Notice No. 50ā from June 24, 2007 (IEC 60825-1 : 2014, EN 60825-1 : 2014)
Typ. light spot size (distance) : 5 mm (+ 2 mm x distance in m)
Max. movement speed : 15 m/s
Acceleration (max.) : = 15 m/s²
1) Statistical error 1 s, environmental conditions constant, min. warm-up time 10 min.
2) From 150 mm ... 180 mm measuring range the accuracy can reach ± 4 mm.
3) Average service life : 100,000 h at TU = +25 °C.
PROFIBUS DP : ?
Number : 2 1)
Type : Push-pull : PNP/NPN
Function : Distance : Distance switching output; Speed; Speed output; Service : Warning message as the sensor ages, if the damping value is exceeded (for example when contaminated, if the permitted interior device temperature is exceeded or undercut, if the measured value has a plausibility error, if the laser is not ready for operation, if the heating is switched on; Laser off; Preset
Maximum output current IA : = 100 mA 2)
Multifunctional input (MF) : 1 x MF1 3)
1) HIGH = > VS - 3 V / LOW = < 2 V.
2) Max. 100 nF/20 mH.
3) HIGH > 12 V / LOW < 3 V.
Electromagnetic compatibility (EMC) : EN 61000-6-2, EN 61000-6-4 1)
Ambient temperature operation :ā20 °C ... +55 °C 2)ā20 °C ... +75 °C, operation with cooling case 2)
Ambient storage temperature : ā40 °C ... +75 °C
Effect of air pressure : 0.3 ppm/hPa
Effect of air temperature : 1 ppm/K
Temperature drift : Typ. 1.0 mm/K
Typ. Ambient light immunity : = 100,000 lx
Mechanical load :Shock : (EN 600 68-2-27)Sine : (EN 600 68-2-6)Noise : (EN 600 68-2-64)
1) This is a Class A device. This device can cause radio interference in living quarters.
2) Temperatures < ā10 °C require warm-up time of typ. 7 minutes.
Shipping Weight : 1.8 Kg