VAA-4E4A-G12-ZAJ/EA2L | Pepperl+Fuchs | Part number : 193672
VAA-4E4A-G12-ZAJ/EA2L | Pepperl+Fuchs | Part number : 193672

VAA-4E4A-G12-ZAJ/EA2L | Pepperl+Fuchs | Part number : 193672

0 Review(s)
USD330.00
Retail Price:USD380.00
Your Savings:USD50.00(13%)
Availability: Estimated Lead Time : 4-6 Weeks
Part Number: VAA-4E4A-G12-ZAJ/EA2L
Manufacturer:Pepperl+Fuchs
Condition : Brand New
Warranty : 12 months 
Write a Review

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com.All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

NII REF No : IAFD111611121121

  • Estimated Lead Time : 4-6 Weeks

  • Manufacturer : Pepperl+Fuchs

  • VAA-4E4A-G12-ZAJ/EA2L

  • AS-Interface sensor/actuator module VAA-4E4A-G12-ZAJ/EA2L

  • One-piece housing with stainless steel base

  • Installation without tools

  • Metal threaded inserts with SPEEDCON technology

  • Flat cable connection with cable piercing technique, variable flat cable guide

  • Red LED per channel, lights up in the event of output overload

  • Communication monitoring, configurable

  • Inputs for 2-, 3-, and 4-wire sensors

  • DIN rail mounting

  • AS-Interface certificate

  • G12 flat module
    4 inputs (PNP) and 4 electronic outputs

  • General specifications

  • Slave type : Standard slave

  • AS-Interface specification : V3.0

  • Required master specification : ? V2.1

  • UL File Number : E223772

  • Functional safety related parameters

  • MTTFd : 190 a

  • Mission Time (TM) : 20 a

  • Diagnostic Coverage (DC) : 0 %

  • Indicators/operating means

  • LED FAULT : error display; LED red
    red: communication error or address is 0
    red flashing: overload of sensor power supply or outputs

  • LED PWR : AS-Interface voltage; green LED
    green: voltage OK
    flashing green: address 0

  • LED AUX : ext. auxiliary voltage UAUX; dual LED green/red
    green: voltage OK
    red: reverse voltage

  • LED IN : switching state (input); 4 LED yellow

  • LED OUT : Switching status (output); 4 yellow/red LEDs 
    Yellow: output active
    Red: output overload

  • Electrical specifications

  • Auxiliary voltage (output) : 24 V DC ± 15 % PELV

  • Rated operating voltage : 26.5 ... 31.6 V from AS-Interface

  • Rated operating current : ≤ 40 mA (without sensors) / max. 240 mA

  • Protection class : III

  • Surge protection : UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral

  • Input

  • Number/Type : 4 inputs for 2- or 3-wire sensors (PNP), DC 
    option 2 inputs for 4-wire sensors (PNP), DC

  • Supply : from AS-Interface

  • Voltage : 21 ... 31 V

  • Current loading capacity : ≤ 200 mA, overload and short-circuit protected

  • Input current : ≤ 8 mA (limited internally)

  • Switching point : according to DIN EN 61131-2 (Type 2)

  • 0 (unattenuated) : ≤ 2 mA

  • 1 (attenuated) : ? 6 mA

  • Signal delay : < 1 ms (input/AS-Interface)

  • Output

  • Number/Type : 4 electronic outputs, PNP, overload and short-circuit proof

  • Supply : from external auxiliary voltage UAUX

  • Current : 2 A per output
    6 A total (TB ≤ 40°C)
    4 A total (TB ≤ 70°C)

  • Voltage : ? (UAUX - 0.5 V)

  • Compliance with standards and directives

  • Directive conformity

  • EMC Directive 2004/108/EC : EN 50295:1999

  • Standard conformity

  • Noise immunity : EN 61000-6-2:2005, EN 50295:1999

  • Emitted interference : EN 61000-6-4:2007

  • Input : EN 61131-2

  • Degree of protection : EN 60529

  • Fieldbus standard : EN 50295, IEC 62026-2

  • Programming instructions

  • Profile : S-7.F

  • IO code : 7

  • ID code : F

  • ID1 code : F

  • ID2 code : E

  • : Data bits (function via AS-Interface) : input output

  • D0 : IN1 OUT1

  • D1 : IN2 OUT2

  • D2 : IN3 OUT3

  • D3 : IN4 OUT4

  • : Parameter bits (programmable via AS-i) : function

  • P0 : communication monitoring
    P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised 
    P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition

  • P1 : Input filter
    P1 = 0 input filter on, pulse suppression ≤ 2 ms
    P1 = 1 input filter off (default settings)

  • P2 : Synchronous mode
    P2 = 0 synchronous mode on
    P2 = 1 synchronous mode off (default settings)

  • P3 : not used

  • Ambient conditions

  • Ambient temperature : -25 ... 70°C (-13 ... 158°F)

  • Storage temperature : -25 ... 85°C (-13 ... 185°F)

  • Relative humidity : 85 % , noncondensing

  • Climatic conditions : For indoor use only

  • Altitude : ≤ 2000 m above MSL

  • Pollution degree : 3

  • Mechanical specifications

  • Degree of protection : IP67

  • Connection : Cable piercing method
    flat cable yellow/flat cable black
    inputs/outputs: M12 round connector

  • Material

  • Housing : PBT

  • Mass : 230 g

  • Tightening torque, cable gland : 0.4 Nm

  • Mounting : Mounting plate

  • Shipping Weight: 1.5 kg

Reward Points

330 points will be rewarded to you when you buy this item.

Related Items

Recently Viewed Items

The cookie settings on this website are set to 'allow all cookies' to give you the very best experience. Please click Accept Cookies to continue to use the site.