QS001CPU
Mitsubishi Electric
  • Estimated Lead Time : Usually ships in 1 - 10 working days.

  • Manufacturer : Mitsubishi Electric

  • QS001CPU

  • Safety CPU Unit QS001 CPU

  • control method : Stored program iteration operation

  • Input / output control method : Refresh method

  • Programming language Sequence control language : Relay symbol word, function block

  • processing speed Sequence instructions LD X 0 : 0.10 μs

  • MOV D 0 D 1 : 0.35 μs

  • Constant scan : 1 ~ 2000 ms (Can be set in 1 ms increments)

  • Program capacity : 14K steps (56 KB)

  • Memory capacity Program memory (drive 0) : 128 KB

  • Standard ROM (Drive 4) : 128 KB

  • Maximum number of stored files Program memory : 3

  • Standard ROM : 3

  • Number of standard ROM writes : Up to 100,000 times

  • Number of input / output devices : 6144 points (X / Y 0 to 17 FF)

  • Number of input / output points : 1024 points (X / Y 0 to 3 FF)

  • Number of device points Internal relay [M] : Default 6144 points (M0 to 6143) (changeable)

  • Link relay [B] : Default 2048 points (B 0 - 7 FF) (changeable)

  • Timer [T] : Default 512 points (T0 to 511) (Shared with low-speed timer / high-speed timer) (Changeable) Low-speed timer / high- speed timer specified by instruction Low-speed timer / high-speed timer measurement unit is set by parameter (low-speed timer: 1 to 1000 ms, 1 ms increment, default 100 ms) (High-speed timer: 0.1 to 100.0 ms, 0.1 ms increments, default 10.0 ms)

  • Integration timer [ST] : Default 0 point (Shared with low speed integration timer / high speed integration timer) (Changeable) Low speed integration timer / high speed integration timer specified by instruction Set the measurement unit of low speed integration timer / high speed integration timer by parameter (low speed integration timer: 1000 ms, 1 ms increment, default 100 ms) (High-speed integration timer: 0.1 to 100.0 ms, 0.1 ms increments, default 10.0 ms)

  • Counter [C] : Normal counter: default 512 points (C 0 to 511) (changeable)

  • Data register [D] : Default 6144 points (D 0 to 6143) (changeable)

  • Link register [W] : Default 2048 points (W 0 to 7 FF) (changeable)

  • Annunciator [F] : Default 1024 points (F0 to 1023) (changeable)

  • Edge relay [V] : Default 1024 points (V 0 to 1023) (changeable)

  • Link special relay [SB] : 1536 points (SB 0 to 5 FF) (Device number is fixed)

  • Link special register [SW] : 1536 points (SW 0 to 5 FF) (the number of device points is fixed)

  • Special relay [SM] : 5120 points (SM 0 to 5 119) (the number of device points is fixed)

  • Special register [SD] : 5120 points (SD 0 to 5119) (the number of device points is fixed)

  • RUN / PAUSE contact : One RUN contact can be set from X 0 to 17 FF P PAUSE No contact

  • Clock function : Accuracy: -3.18 to +5.25 s (TYP. + 2.14 s) / d at 0 ° C Accuracy: -3.18 to +2.59 s (TYP. + (Year), month, day, hour, minute, 2.07 s) / d at 25 ° C Accuracy: -12.97 to + 3.63 s (TYP. -3.16 s) / d at 55 ° C

  • Allowable momentary power failure time : Depends on power supply unit

  • DC 5 V Internal current consumption : 0.58 A

  • External dimensions Height (H) : 98 mm

  • Width (W) : 55.2 mm

  • Depth (D) : 114 mm

  • mass : 0.29 Kg

  • Protection grade : IP2X

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -40 to 75 ° C

  • Ambient operating humidity : 5 to 95% RH, non condensing

  • Storage ambient humidity : 5 to 95% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , working time 11 ms, three times in XYZ three directions with sine half-wave pulse)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Device class : Class I

  • Shipping Weight : 1.3 Kg

[short_review]
[long_review]
Did you find this helpful?  [rev_helpful] of [rev_votes] Found Helpful
Reviewed by: (Verified Buyer)  from [user_city]. [user_email] on [review_date]
[rating]
There are no reviews for this product!

Reward Points

2254 points will be rewarded to you when you buy this item.

Related Items

https://www.nexinstrument.com/assets/images/06092018MitsubishiElectric/thumbnail/124.png

Feature 5

Price USD X1.4=USD SELLING PRICE

Recently Viewed Items

Legal Disclaimer

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.