NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Q26UDHCPU

  • Universal model QCPU Q 26 UDHCPU

  • control method : Stored program iteration operation

  • Input / output control method : Refresh method (Direct access input / output possible by specifying direct access input / output (DX, DY))

  • Programming language Sequence control language : Relay symbol word, logic symbolic word, MELSAP 3 (SFC), MELSAP-L, function block, structured text (ST)

  • processing speed Sequence instructions LD X 0 : 9.5 ns

  • MOV D 0 D 1 : 19 ns

  • Constant scan : 0.5 - 2000 ms (Can be set in 0.5 ms increments)

  • Program capacity : 260 K steps (1040 K bytes)

  • Memory capacity Program memory (drive 0) : 1040 KB

  • Memory card (RAM) (Drive 1) : Amount of installed memory card capacity (maximum 8 Mbytes)

  • Memory card (ROM) (Drive 2) : (Flash card: up to 4 Mbytes, ATA card: up to 32 Mbytes)

  • Standard RAM (Drive 3) : 1280 KB

  • Standard ROM (Drive 4) : 4096 KB

  • CPU shared memory QCPU standard area : 8 KB

  • High speed communication area between multiple CPUs : 32 KB

  • Maximum number of stored files Program memory : 252 books

  • Memory card (RAM) : 319 (when using Q3MEM-8 MBS)

  • Memory card (ROM) Flash card : 288 books

  • ATA card : 511 books

  • Standard RAM : 4

  • Standard ROM : 256

  • Intelligent functional unit Parameter Maximum setting number Initial setting : 4096 pieces

  • refresh : 2048 pieces

  • Number of input / output devices : 8192 points (X / Y 0 to 1 FFF)

  • Number of input / output points : 4096 points (X / Y 0 to FFF)

  • Number of device points Internal relay [M] : Default 8192 points (M0 to 8191) (changeable)

  • Latch relay [L] : Default 8192 points (L0 to 8191) (changeable)

  • Link relay [B] : Default 8192 points (B 0 to 1 FFF) (changeable)

  • Timer [T] : Default 2048 points (T0 to 2047) (Shared by low-speed timer / high-speed timer) (Changeable) Low-speed timer / high- speed timer specified by instruction Low-speed timer / high-speed timer measurement unit is set by parameter (low-speed timer: 1 to 1000 ms, 1 ms increment, default 100 ms) (High-speed timer: 0.1 to 100.0 ms, 0.1 ms increments, default 10.0 ms)

  • Integration timer [ST] : Default 0 point (Shared with low speed integration timer / high speed integration timer) (Changeable) Low speed integration timer / high speed integration timer specified by instruction Set the measurement unit of low speed integration timer / high speed integration timer by parameter (low speed integration timer: 1000 ms, 1 ms increment, default 100 ms) (High-speed integration timer: 0.1 to 100.0 ms, 0.1 ms increments, default 10.0 ms)

  • Counter [C] : Normal counter: default 1024 points (C 0 ~ 1023) (changeable)

  • Data register [D] : Default 12288 points (D 0 to 12287) (changeable)

  • Extended data register [D] : Default 0 point (changeable)

  • Link register [W] : Default 8192 points (W 0 to 1 FFF) (changeable)

  • Extended link register [W] : Default 0 point (changeable)

  • Annunciator [F] : Default 2048 points (F 0 to 2047) (changeable)

  • Edge relay [V] : Default 2048 points (V 0 to 2047) (changeable)

  • File register [R] Standard RAM : 32768 points (R 0 ~ 32767) Up to 655360 points can be used by block switching

  • SRAM card (1 Mbyte) : 32768 points (R 0 ~ 32767) Maximum 517120 points can be used by block switching

  • SRAM card (2 Mbytes) : 32768 points (R 0 to 32767) Maximum 1041408 points can be used by block switching

  • SRAM card (4 Mbytes) : 32768 points (R 0 ~ 32767) Up to 2087936 points can be used by block changeover

  • SRAM card (8 Mbytes) : 32768 points (R 0 ~ 32767) Up to 4184064 points can be used by block changeover

  • Flash card (2 Mbytes) : 32768 points (R 0 to 32767) Maximum 1041408 points can be used by block switching

  • Flash card (4 Mbytes) : 32768 points (R 0 ~ 32767) Up to 2087936 points can be used by block changeover

  • File register [ZR] Standard RAM : 655360 points (ZR 0 to 655359) Block switching unnecessary

  • SRAM card (1 Mbyte) : 517120 points (ZR 0 to 517119) No block switching required

  • SRAM card (2 Mbytes) : 1041408 points (ZR 0 to 1041407) No block switching required

  • SRAM card (4 Mbytes) : 2087936 points (ZR 0 to 2087935) Block switching not required

  • SRAM card (8 Mbytes) : 4184064 points (ZR 0 to 4184063) Block switching not required

  • Flash card (2 Mbytes) : 1041408 points (ZR 0 to 1041407) No block switching required

  • Flash card (4 Mbytes) : 2087936 points (ZR 0 to 2087935) Block switching not required

  • Link special relay [SB] : Default 2048 points (SB 0 to 7 FF) (changeable)

  • Link special register [SW] : Default 2048 points (SW 0 to 7 FF) (changeable)

  • Step relay [S] : Default 8192 points (S0 to 8191) (changeable)

  • Index register / general operation register [Z] : Up to 20 points (Z 0 ~ 19)

  • Index register [Z] (when 32-bit qualification of ZR device is specified) : Up to 10 points (Z0 to 18) (Use index register [Z] as double word)

  • Pointer [P] : 4096 points (P 0 ~ 4095) (Number of device points fixed) Use range of local pointer / common pointer can be set by parameter

  • Interrupt pointer [I] : 256 points (I 0 to 255) (the number of device points is fixed) Periodic interval of system interrupt pointer I 28 to 31 can be set by parameter (0.5 to 1000.0 ms, 0.5 ms increments) Default I 28: 100 ms, I 29: 40 ms, I 30: 20 ms , I31: 10 ms

  • Special relay [SM] : 2048 points (SM 0 to 2047) (Device number is fixed)

  • Special register [SD] : 2048 points (SD 0 to 2047) (the number of device points is fixed)

  • Function input [FX] : 16 points (FX 0 to F) (Device number is fixed)

  • Function output [FY] : 16 points (FY 0 to F) (the number of device points is fixed)

  • Function register [FD] : 5 points (FD 0 ~ 4) (Device number is fixed)

  • Link direct device : J□□ \ X□□, J□□ \ Y□□, J□□ \ SB□□, J□□ \ SB□□, J□□ \ SB□□, J□□ \ SW□□, J□□ \ SW□ Device specification form for directly accessing the link device of the network unit□

  • Intelligent functional unit device : Device specification that directly accesses buffer memory of intelligent function module Format: U□□ \ G□□

  • Latch (power outage hold) range : L 0 to 8191 (default 8192 points) [latch range can be set for B, F, V, T, ST, C, D, W]

  • RUN / PAUSE contact : One point of each RUN / PAUSE contact can be set from X 0 to 1 FFF

  • Clock function : Year, month, day, hour, minute, second, day of the week (leap year automatic discrimination) accuracy: -2.96 ~ + 3.74s (. TYP + 1.42s) / d at 0 °C accuracy: -3.18 ~ + 3.74s (TYP + . 1.50 s) / d at 25 ° C. Accuracy: -13.20 to +2.12 s (TYP. -3.54 s) / d at 55 ° C.

  • Allowable momentary power failure time : Depends on power supply unit

  • DC 5 V Internal current consumption : 0.39 A

  • External dimensions Height (H) : 98 mm

  • Width (W) : 27.4 mm

  • Depth (D) : 89.3 mm

  • mass : 0.20 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -25 to 75 ° C (-20 to 75 ° C when system includes AnS / A series unit)

  • Ambient operating humidity : 5 to 95% RH, non condensing (10 to 90% RH when the system includes AnS / A series unit)

  • Storage ambient humidity : 5 to 95% RH, non condensing (10 to 90% RH when the system includes AnS / A series unit)

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Device class : Class I

  • Shipping Weight : 1.2 Kg