Estimated Lead Time : 4-6 Weeks
Manufacturer : SICK Sensors
PBSH-RB010S54S0BMA0Z
Medium : Liquid, gaseous
Pressure type : Gauge pressure
Measuring range : 0 bar ... 10 bar
Overpressure safety : 2-fold
Process temperature : –20 °C ... +100 °C, +135 °C for max. 1 h
Maximum ohmic load RA : ≤ 0.5 kΩ
Zero point adjustment : Max. + 3 % of span
Output signal : 1 x PNP + 4 mA ... 20 mA
Rotatable housing :Display against housing with electrical connection: 330 °
Housing against process connection: 320 °
Display :14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°
Accuracy: ≤ 1 % of span ± 1 digit
Update: 1,000, 500, 200, 100 ms (adjustable)
EHEDG approval : ✓ 1)
1) EHEDG conformity with connection per DIN 11851 only in combination with ASEPTO-STAR k-flex upgrade, sealing from Kieselmann GmbH.
Process connection : Conical coupling (DIN 11851) DN 40 with union nut
Wetted parts : Stainless steel 1.4435 / 316L
Internal transmission fluid : Medical white oil, FDA compliant according to
CFR 172.878 and 21 CFR 178.3620(a), compliant to USP, EP, and JP
Housing material : Lower body: stainless steel 304, Plastic head: PC + ABS,
Buttons: TPE-E, Display window: PC
Connection type : M12 round connector x 1, 4-pin
Supply voltage : 15 V DC ... 35 V DC
Power consumption : Max. 70 mA
Total current consumption : Max. 320 mA (incl. switching current)
Protection class: III
Overvoltage protection: 40 V DC
Short-circuit protection: QA, Q1, Q2 towards M
Reverse polarity protection: L+ to M
Isolation voltage : 500 V DC
CE-conformity : EMC directive: 2004/108/EC, EN 61326-2-3
Seal : Without seal
Enclosure rating : IP65 / IP67
Protection class III : ✓
Non-linearity : ≤ ± 0.5 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
Accuracy : ≤ ± 1 % of the span
Setting accuracy of switching outputs : ≤ ± 0.5 % of span
Response time : 3 ms
Long-term drift/one-year stability : ≤ ± 0.2 % of the span according to IEC 61298-2
Temperature coefficient in rated temperature range : Typical TC of the zero
point: in temperature range 0 °C ... 20 °C: 0.7% of the range / 10 K; in
temperature range 20 °C ... 80 °C: 0.2% of span / 10 K.
Typical TC of span: in temperature range 0 °C ... 80 °C: 0.1% of span / 10 K
Rated temperature range : 0 °C ... +80 °C
Ambient temperature : –20 °C ... +80 °C
Storage temperature : –20 °C ... +80 °C
Relative humidity : 45 % ... 75 %
Shock load : 50 g according to IEC 60068-2-27 (mechanical shock)
Vibration load : 10 g according to IEC 60068-2-6 (vibration under resonance)
Shipping Weight : 1 Kg