NBN40-U1K-E2-3G-3D | Pepperl+Fuchs | Part number : 209264
NBN40-U1K-E2-3G-3D | Pepperl+Fuchs | Part number : 209264

NBN40-U1K-E2-3G-3D | Pepperl+Fuchs | Part number : 209264

0 Review(s)
USD174.00
Retail Price:USD200.00
Your Savings:USD26.00(13%)
Availability: Estimated Lead Time : 4-6 Weeks
Part Number: NBN40-U1K-E2-3G-3D
Manufacturer:Pepperl+Fuchs
Condition : Brand New
Warranty : 12 monthsĀ 
Write a Review

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com.All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

NII REF No : IAFD111611121121

  • Estimated Lead Time : 4-6 Weeks

  • Manufacturer : Pepperl+Fuchs

  • NBN40-U1K-E2-3G-3D

  • Inductive sensor NBN40-U1K-E2-3G-3D

  • Sensor head bidirectional and rotatable

  • 40 mm non-flush

  • 3-wire DC

  • 4 LEDs indicator for 360° visibility

  • ATEX-approval for zone 2 and zone 22

  • Switching function : Normally open (NO)

  • Output type : PNP

  • Rated operating distance : 40 mm

  • Installation : non-flush

  • Output polarity : DC

  • Assured operating distance : 0 ... 32.4 mm

  • Actual operating distance : 36 ... 44 mm typ. 40 mm

  • Reduction factor rAl : 0.31

  • Reduction factor rCu : 0.3

  • Reduction factor r304 : 0.74

  • Reduction factor rBrass : 0.39

  • Nominal ratings

  • Operating voltage : 10 ... 30 V DC

  • Switching frequency : 0 ... 150 Hz

  • Hysteresis : typ. 5 %

  • Reverse polarity protection : reverse polarity protected

  • Short-circuit protection : pulsing

  • Voltage drop : ≤ 2 V

  • Voltage drop at IL

  • Voltage drop ILĀ = 1Ā mA, switching element on : 0.5 ... 2.3 V typ. 0.9 V

  • Voltage drop ILĀ = 10Ā mA, switching element on : 0.8 ... 2.2 V typ. 1.4 V

  • Voltage drop ILĀ = 20Ā mA, switching element on : 0.9 ... 2.3 V typ. 1.5 V

  • Voltage drop ILĀ = 50Ā mA, switching element on : 0.9 ... 2.5 V typ. 1.6 V

  • Voltage drop ILĀ = 100Ā mA, switching element on : 1 ... 2.6 V typ. 1.8 V

  • Voltage drop ILĀ = 200Ā mA, switching element on : 1.2 ... 2.8 V typ. 2 V

  • Operating current : 0 ... 200 mA

  • Off-state current : 0 ... 0.5 mA typ. 0.01 mA

  • Off-state current TU=40 °C, switching element off : ≤ 100 μA

  • No-load supply current : ≤ 20 mA

  • Operating voltage indicator : LED, green

  • Switching state indicator : LED, yellow

  • Functional safety related parameters

  • MTTFd : 1358 a

  • Mission Time (TM) : 20 a

  • Diagnostic Coverage (DC) : 0 %

  • Approvals and certificates

  • FM approval : hazardous (classified) locationĀ 
    Non-incendive

  • UL approval : cULus Listed, General Purpose

  • CSA approval : cCSAus Listed, General Purpose

  • CCC approval : CCC approval / marking not required for products rated ≤36 V

  • Ambient conditions

  • Ambient temperature : -25 ... 85 °C (-13 ... 185 °F)

  • Mechanical specifications

  • Connection type : screw terminals

  • Information for connection : A maximum of two conductors with the same core cross section may be mounted on one terminal connection!Ā 
    tightening torque 1.2 Nm + 10 %

  • Core cross-section : up to 2.5 mm2

  • Minimum core cross-section : without wire end ferrule 0.5 mm2Ā , with connector sleeves 0.34 mm2

  • Maximum core cross-section : without wire end ferrule 2.5 mm2Ā , with connector sleeves 1.5 mm2

  • Housing material : PA/metal

  • Sensing face : PA

  • Degree of protection : IP68 / IP69K

  • Mass : 225 g

  • Note : Tightening torque: 1.8 Nm (housing)

  • Equipment protection level Gc (nA)

  • Certificate : PF 15CERT3754 X

  • : Special conditions

  • Protection against transients : Ensure transient protection is provided and that the maximum value of the transient protection (140% of 85 V) is not exceeded.

  • Equipment protection level Dc (tc)

  • : Instruction : Manual electrical apparatus for hazardous areas

  • : Device category 3D : for use in hazardous areas with combustible dust

  • Certificate : PF 15CERT3774 X

  • CE marking : [*PD-Z02586A*]

  • ATEX marking : Ex-HexagonĀ II 3D Ex tc IIIC T80°C DcĀ 
    The Ex-related marking can also be printed on the enclosed label.

  • Standards : EN 60079-0:2012+A11:2013, EN 60079-31:2014Ā 
    Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.

  • General : The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.

  • Installation, commissioning : Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again.

  • Maintenance : No changes can be made to apparatus, which are operated in hazardous areas.
    Repairs to these apparatus are not possible. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again.

  • : Special conditions

  • Maximum operating current IL : The maximum permissible load current must be restricted to the values given in the following list.
    High load currents and load short-circuits are not permitted.

  • Maximum operating voltage UBmax : The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.

  • Maximum permissible ambient temperature TUmax : dependant of the load current ILĀ and the max. operating voltage UBmax
    Information can be taken from the following list.

  • at UBmax=30 V, IL=200 mA : 50 °C (122 °F)

  • at UBmax=30 V, IL=100 mA : 53 °C (127.4 °F)

  • at UBmax=30 V, IL=50 mA : 54 °C (129.2 °F)

  • Protection from mechanical danger : The sensor must not be exposed toĀ ANY FORMĀ of mechanical danger.

  • Protection from UV light : The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.

  • Electrostatic charge : Sliding contact discharges must be avoided. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TSĀ 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.

  • Lead insertion : If cable glands are required for the installation then the following points must be observed:Ā The cable glands must be certified in accordance with the application.Ā The temperature range of the cable glands must be selected according to the application.Ā The degree of protection must not be reduced by the cable glands. Seal the housing. Use a seal that meets the requirements of the application.

  • Plug connector : The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted)

  • General information

  • Use in the hazardous area : see instruction manuals

  • Category : 3G; 3D

  • Shipping Weight: 1.5 kg

Reward Points

174 points will be rewarded to you when you buy this item.

Related Items

Recently Viewed Items

The cookie settings on this website are set to 'allow all cookies' to give you the very best experience. Please click Accept Cookies to continue to use the site.