Frequency Converter with Trip Values KFD2-UFC-1.D

Frequency Converter with Trip Values KFD2-UFC-1.D

Your Price: $382.00
Retail Price:$439.00
Your Savings:$57.00(13%)
Estimated Lead Time : In stock. Usually ships in 7-10 working days.
Part Number:KFD2-UFC-1.D

Condition : Brand New

Warranty : 12 months 

You need to be a registered customer to order this product. Please Login to your account or click here to Register.

Sign in with Facebook

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

  • Estimated Lead Time : 7 Working Days

  • Manufacturer : Pepperl+Fuchs

  • Frequency Converter with Trip Values KFD2-UFC-1.D

  • 1-channel signal conditioner

  • 24 V DC supply (Power Rail)

  • Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts

  • Input frequency 1 mHz ... 12 kHz

  • Current output 0/4 mA ... 20 mA

  • Relay and transistor output

  • Start-up override

  • Line fault detection (LFD)

  • Up to SIL 2 acc. to IEC 61508

  • General specifications

  • Signal type : Digital Input

  • Supply

  • Connection : terminals 23+, 24- or power feed module/Power Rail

  • Rated voltage : 20 ... 30 V DC

  • Rated current : approx. 100 mA

  • Power dissipation/power consumption : ≤ 2 W / 2.2 W

  • Input

  • Connection : Input I: 2-wire sensor: terminals 1+, 3- three wire sensor: terminals 1+, 2- and 3
    input II: terminals 13+, 14- start-up override;

  • Input I : 2- or 3-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact

  • Open circuit voltage/short-circuit current : 22 V / 40 mA

  • Input resistance : 4.7 kΩ

  • Switching point/switching hysteresis : logic 1: > 2.5 mA ; logic 0: < 1.9 mA

  • Pulse duration : > 50 µs

  • Input frequency : 0.001 ... 12000 Hz

  • Lead monitoring : breakage I ≤ 0.15 mA; short-circuit I > 4 mA

  • Input II : startup override: 1 ... 1000 s, adjustable in steps of 1 s

  • Active/Passive : I > 4 mA (for min. 100 ms) / I < 1.5 mA

  • Open circuit voltage/short-circuit current : 18 V / 5 mA

  • Output

  • Connection : output I: terminals 10, 11, 12
    output II: terminals 16, 17, 18
    outout III: terminasl 19+, 20-
    output IV: terminals 8+, 7-

  • Output I, II : signal, relay

  • Contact loading : 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A

  • Mechanical life : 5 x 107 switching cycles

  • Energized/De-energized delay : approx. 20 ms / approx. 20 ms

  • Output III : electronic output, passive

  • Contact loading : 40 V DC

  • Signal level : 1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof)
    0-signal: blocked output (off-state current ≤ 10 µA)

  • Output IV : analog

  • Current range : 0 ... 20 mA or 4 ... 20 mA

  • Open loop voltage : max. 24 V DC

  • Load : max. 650 Ω

  • Fault signal : downscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43)

  • Collective error message : Power Rail

  • Transfer characteristics

  • Output IV

  • Resolution : < 10 µA

  • Accuracy : < 20 µA

  • Influence of ambient temperature : 0.005 %/K (50 ppm)

  • Directive conformity

  • Electromagnetic compatibility

  • Directive 2004/108/EC : EN 61326-1:2006

  • Low voltage

  • Directive 2006/95/EC : EN 50178:1997

  • Conformity

  • Insulation coordination : IEC 62103

  • Galvanic isolation : IEC 62103

  • Electromagnetic compatibility : NE 21:2006

  • Degree of protection : IEC 60529:2001

  • Ambient conditions

  • Ambient temperature : -20 ... 60 °C (-4 ... 140 °F)

  • Mechanical specifications

  • Degree of protection : IP20

  • Mass : 300 g

  • Dimensions : 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3

  • Mounting : DIN rail mounting

  • Data for application in connection with hazardous areas

  • Statement of conformity : Pepperl+Fuchs

  • Group, category, type of protection, temperature class : II 3G Ex nA nC IIC T4

  • Output I, II

  • Contact loading : 50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive load

  • Directive conformity

  • Directive 94/9/EC : EN 60079-0:2006, EN 60079-15:2005

  • Shipping Weight : 1 Kg