High speed output adapter FX 3 U - 2 HSY - ADP

High speed output adapter FX 3 U - 2 HSY - ADP

Your Price: $515.20
Retail Price:$592.00
Your Savings:$76.80(13%)
Estimated Lead Time : In stock. Usually ships in 7-10 working days.
Part Number:FX3U-2HSY-ADP

Condition : Brand New

Warranty : 12 months 

You need to be a registered customer to order this product. Please Login to your account or click here to Register.

Sign in with Facebook

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • FX3U-2HSY-ADP

  • High speed output adapter FX 3 U - 2 HSY - ADP

  • Number of control axes : Independent 2 axes (2 units connected and independent 4 axes controllable)

  • Pulse output method : Differential line driver system

  • Pulse output form : Pulse train + direction, forward rotation / reverse rotation pulse train

  • Maximum frequency : 200 kHz

  • Acceleration / deceleration processing : Depending on the sequence program

  • Control unit : pulse

  • Positioning range : Depending on the sequence program

  • Programming language : Sequence program

  • Position data : 1 point (set by sequence program)

  • Absolute position detection (ABS current value reading) : Use sequencer's ABS command

  • Number of occupied I / O points : When connecting one FX 3 U - 2 HSY - ADP, use the outputs Y000, Y001, Y004, Y005 of the basic unit. In the case of connecting two units, use the outputs Y000 to Y007 of the basic unit.

  • Application sequencer : FX3U

  • mass : 0.08 Kg

  • Power-supply voltage : DC 5 V 30 mA ( internal power supply from the sequencer ) DC 24 V 60 mA ( internal power supply from the service power supply of the sequencer)

  • Number of output points : When 4 points are connected: Y000, Y001, Y004, Y005 are assigned. When two units are connected: Y000 to Y007 are assigned. (FX 3 U - 2 HSY - ADP Output terminals of the sequencer body with the same number can not be used.)

  • Output form : You can select forward rotation (FP) / reverse rotation (RP) or pulse (PLS) / direction (DIR).

  • Output method : Differential line driver output

  • Output frequency : 200 kHz

  • Operation indication : LED on when output is ON

  • Ambient temperature : 0 to 55 ° C. ... Operating, -25 to 75 ° C. ..... Save

  • Relative humidity : 5 to 95% RH (noncondensing).... in operation

  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)

  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)

  • Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse

  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si

  • tor with period of 30 to 100 Hz

  • Withstand voltage : High-speed output Between the output terminal of the special adapter and the earth terminal of the PLC main unit: AC 500 V for 1 minute

  • Insulation resistance : High-speed output Between the output terminal of the special adapter and the earth terminal of the programmable controller main body: 500 MV DC, 5 MΩ or more with the insulation resistance meter

  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

  • Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

  • Shipping Weight : 1 Kg