NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • FX3U-2HC

  • High speed counter block FX 3 U - 2 HC

  • Number of input channels : 2 ch

  • Input format : Open collector, differential line driver (Differential line driver output type encoder is connected to 5 V terminal)

  • Input voltage : DC 5 V, DC 12 V, DC 24 V can be selected by connection terminal

  • Maximum response frequency 1 phase 1 input : 200 kHz or less

  • 1 phase 2 input : 200 kHz or less

  • 2 phase input : 200 kHz or less (1 multiplication), 100 kHz or less (2 multiplication), 50 kHz or less (4 multiplication)

  • Count range : When 32 bits are specified: -2, 147, 483, 648 to +2, 147, 483, 647 When 16 bits are specified: 0 to 65,535 (upper limit value can be specified by BFM # 3, # 2, # 43,

  • Count mode : Automatic up / down (However, the count direction is determined by the following command of 1 phase 1 input counter.) [H / W up / down] Up / down counting is performed by OFF / ON of A phase input terminal. [S / W up / down] Up / down is performed with the current value (K0 / K1) of BFM # 1, # 41.

  • Matching output (comparison) : When the current value of the counter matches the comparison setting value, the comparison output is set (ON) within 30 μs and cleared (OFF) within 100 μs by the reset command.

  • Output format : Open collector output 2 points 5 VDC to 24 V 0.5 A

  • Display (LED) : φ A, φ B, DIS, PRE, YH 1, YH 2, POWER, UP, DOWN

  • Number of occupied I / O points : 8 points (either input or output may be considered)

  • Application sequencer :For connection to FX5U, FX5UC, FX5 - CNV - BUS or FX5 - CNV - BUSC is connected to FX5U, FX5U, FX3U (V2.20 or higher), FX3UC Is required. Depending on the system configuration, please choose either.To connect to FX3UC, FX2NC - CNV - IF or FX3UC - 1PS - 5V is required.

  • mass : 0.2 Kg

  • Power supply : DC 5 V 245 mA (internal power supply from the sequencer)

  • Ambient temperature : 0 to 55 ° C. ... Operating -25 to 75 ° C. ..... Save

  • Relative humidity : 5 to 95% RH (noncondensing).... in operation

  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)

  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)

  • Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse

  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si

  • tor with period of 30 to 100 Hz

  • Withstand voltage : Between all terminals and ground terminal: 500 VAC for 1 minute

  • Insulation resistance : Between all terminals and ground terminal: 500 MV DC 500 MΩ or more with an insulation resistance meter

  • ground : Class D grounding (grounding resistance: 100 Ω or less)Grounding should be dedicated ground or common ground.

  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

  • Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

  • Shipping Weight : 1.2 Kg