Estimated Lead Time : Usually ships in 1 - 10 working days.
-
Manufacturer : Mitsubishi Electric
-
Product No. : FX3U-1PG
-
Product Type : Pulse output block FX 3 U - 1 PG
-
Number of control axes : 1 axis
-
Positioning program : Created by sequence program (use direct specification of buffer memory such as FROM / TO instruction or MOV instruction)
-
Positioning: -
-
method : Increment, Absolute
-
unit : PLS, µm, 10 -4 inch, mdeg
-
Unit magnification : 1, 10, 100, 1000 times
-
range : -2, 147, 483, 648 to 2, 147, 483, 647 PLS
-
Speed ??command : Hz, cm / min, inch / min, 10 deg / min
-
Output frequency : Output frequency 1 Hz to 200 kHz
-
Acceleration / deceleration processing : Trapezoidal acceleration / deceleration: 1 to 32,767 ms approximate S-shaped acceleration / deceleration: 1 to 5,000 ms
-
Start-up time : Motor system: 1 ms or less Mechanical system: 2 ms or less
-
Number of occupied I / O points : 8 points (It can count either input or output)
-
Application sequencer : About connection to FX5U, FX5UC CPU Unit> For connection to FX5U, FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC are connected to FX5U, FX5U, FX3U (Ver.2.20 or later), FX3UC Is required. Depending on the system configuration, please choose either. To connect to FX3UC, FX2NC - CNV - IF or FX3UC - 1PS - 5V is required.
-
Power supply specification :
-
Drive power supply: -
-
For input signal : For input signal DC 24 V ± 10% Consumption current 40 mA or less
-
For output signal : For pulse output: DC 5 to 24 V DC consumption current 35 mA or less For CLR signal: DC 5 to 24 V DC consumption current 20 mA or less
-
For internal control : DC 5 V Consumption current 150 mA (Power is supplied from the sequencer body via extension cable)
-
Input specification: -
-
Input signal name: -
-
Group 1 STOP : Used for interrupt input during deceleration stop input or external command positioning, interruption 2-speed positioning operation
-
Group 1 DOG : DOG type Used for interrupt input during DOG input or external command positioning during machine home return operation, interrupt 1st speed positioning, interrupt stop, interrupt 2nd speed positioning operation
-
Group 2 PG 0 : Zero point signal input DOG type Used in machine home return operation
-
Group 1: -
-
Signal voltage : DC 24 V (power supplied from S / S terminal)
-
Input current : 7.0 mA
-
ON current : 4.5 mA or more
-
OFF current : 1.5 mA or less
-
Signal type : No-voltage contact input At sink input: NPN open collector transistor Source input: PNP open collector transistor
-
Response time : DOG input: 1 ms STOP input: 4 ms
-
Circuit insulation : Photocoupler insulation
-
Input operation display : LED ON when input is ON
-
Group 2: -
-
Signal voltage : DC 5 to 24 V
-
Input current : 20 mA or less
-
ON current : 4.0 mA or more
-
OFF current : 0.5 mA or less
-
Signal type : NPN open collector transistor
-
Response pulse width : 4 µs or more
-
Circuit insulation : Photocoupler insulation
-
Input operation display : LED ON when input is ON
-
Output specification :
-
Output signal name: -
-
Group 1 FP : Forward pulse or pulse train
-
RP : Reverse rotation pulse or rotation direction signal
-
Group 2 CLR : CLR signal
-
Group 1: -
-
Output format : A transistor
-
Output method : You can select forward rotation pulse (FP) / reverse rotation pulse (RP) or pulse (PLS) / direction (DIR)
-
Output frequency : 1 Hz to 200 kHz
-
Rated load voltage : DC 5 to 24 V
-
Maximum load current : 20 mA or less
-
VIN consumption current : DC 5 to 24 V 35 mA or less
-
Output ON voltage : Below 1.0V
-
Output operation indication : LED on when output is ON
-
Group 2: -
-
Output format : A transistor
-
Output method : Pulse (output pulse width: 20 ms)
-
Rated load voltage : DC 5 to 24 V
-
Maximum load current : 20 mA or less
-
Output ON voltage : 1.5V or less
-
Output operation indication : LED on when output is ON
-
Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)
-
Anti-vibration When DIN rail is installed Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
-
Anti-vibration Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)
-
Anti-vibration Direct installation Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)
-
Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse
-
Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 µs, rising 1 ns, with noise si
-
tor with period of 30 to 100 Hz
-
Withstand voltage : Between all terminals and ground terminal: 500 VAC for 1 minute
-
Insulation resistance : Between all terminals and ground terminal: 500 MV DC 500 MO or more with an insulation resistance meter
-
Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
-
Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
- Weight : 0.2 Kg
-
Shipping Weight : 1.5 Kg