FX3U-16CCL-M | Mitsubishi Electric | CC-Link system master block FX 3 U - 16 CCL - M

FX3U-16CCL-M | Mitsubishi Electric | CC-Link system master block FX 3 U - 16 CCL - M

Your Price: $172.20
Retail Price:$198.00
Your Savings:$25.80(13%)
Estimated Lead Time : In stock. Usually ships in 7-10 working days.
Part Number:FX3U-16CCL-M

Condition : Brand New

Warranty : 12 months 

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

  • Estimated Lead Time : In stock. Usually ships in 5-7 working days.

  • Manufacturer : Mitsubishi Electric

  • CC-Link version : Ver.2.00 (Ver.1.10 is also supported)

  • Station type : Master station (local station, standby master station function not available)

  • Transmission speed : 156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps selectable (set with rotary switch)

  • Station number : 0 (set with rotary switch)

  • Maximum cable total extension (maximum transmission distance) : Different according to transmission speed up to 1200 m

  • Maximum number of connected stations Remote I / O station : Up to 8 stations (occupying the real I / O 32 points of the sequencer per one station)

  • Remote device station + intelligent device station total : Up to 8 stations (total score of RX / RY is 256 or less each)

  • Maximum input / output points per system FX3U / FX3UC PLC : Total of 1) + 2) = 384 1) (Sequencer real I / O points) + (Number of occupied I / O occupied points of special expansion block) + (Number of input / output occupied points of 16 CCL - M: 8 points) = 256 2) 32 number of stations of remote I / O station = 256 points

  • FX 3 G / FX 3 GC Sequencer : 32 Number of stations of remote I / O station 128 points

  • Number of links per station : 32 points Remote register (RWw): 4 points (Master station Remote device station / Intelligent device station) Remote register (RWr): 4 points (Remote device station / Intelligent device station Master Station) . The Above Is The Number Of Link Points In Remote Net Ver.1 Mode Refer To "FX 3 U - 16 CCL - M User 'S Manual (JY 997 D 43501)" For The Number Of Link Points In Remote Net Ver. 2 mode and Remote Net Addition mode.

  • Communication method : Broadcast polling method

  • Synchronization method : Frame synchronization method

  • Coding scheme : NRZI system

  • Transmission path format : Bus (RS-485)

  • Transmission format : HDLC compliant

  • Error control method : CRC (X 16 + X 12 + X 5 + 1)

  • Connection cable : CC-Link dedicated cable / Ver. 1.10 compatible CC-Link dedicated cable CC-Link dedicated cable, CC-Link dedicated high-performance cable, Ver.1.10 compatible CC-Link dedicated cable It can Be Mixed Not. Also, Please Attach A Terminating Resistor Matching The Type Of Cable.

  • RAS function : Automatic return function, Slave station detachment function, Abnormality detection by link special relay / register

  • Communicate with the sequencer : Execute via buffer memory with FROM / TO instruction or direct specification of buffer memory (FX3U / FX3UC).

  • Display (LED) : RUN, ERR., L RUN, L ERR. , SD, RD, POWER

  • Number of occupied I / O points : 8 points (It can count either input or output)

  • Application sequencer : FX3U -16CCL-M, FX2N-16CCL-M can not be used with FX2N-32ASI-M in combination with FX5U, FX5UC, FX3G, FX3U (Ver.2.20 or later), FX3GC, FX3UC (Ver.2.20 or later) .

  • It is not possible to use FX 3 U - 16 CCL - M and FX 2 N - 16 CCL - M together.

  • To connect to FX5U, FX5UC, FX5 - CNV - BUS or FX5 - CNV - BUSC is required. Depending on the system configuration, please choose either.

  • To connect to FX 3 GC, FX 3 UC, FX 2 NC - CNV - IF or FX 3UC - 1 PS - 5 V is required.

  • Mass : 0.3 kg

  • Power supply specification

  • Power supply External power supply : DC 24 V + 20% - 15% ripple (pp) within 5%

  • Internal power supply : 5 V DC 5 V of the sequencer is not used. (24 VDC external power supply is converted to DC 5 V and power is supplied.) Please observe the power supply turning on timing and procedure and use it.

  • Current consumption : 24 VDC external power supply: 240 mA

  • Ambient temperature Relative humidity Impact resistance Noise immunity Withstand voltage Insulation resistance ground Use atmosphere Use altitude : 0 to 55 o C. &bull&bull&bull Operating -25 to 75 o C. &bull&bull&bull&bull&bull Save, : 5 to 95% RH (noncondensing)&bull&bull&bull&bull in operation.

  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)

  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)

  • 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse

  • Noise voltage with 1,000 Vp-p, noise width 1 us, rising 1 ns, with noise simulator with period of 30 to 100 Hz

  • Between all terminals and ground terminal: 500 VAC for 1 minute

  • Between all terminals and ground terminal: 500 MV DC 500 MO or more with an insulation resistance meter

  • Class D grounding (grounding resistance: 100 O or less) Grounding must be dedicated ground or common ground.

  • There is no corrosive property, flammable gas, conductive dust (dust) is not serious

  • Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
  • Shipping Weight: 2 kg