FX2N-80MT-ES/UL
Mitsubishi Electric
  • Estimated Lead Time: Usually ships in 1 - 10 working days.

  • Manufacturer: Mitsubishi Electric

  • FX2N-80MT-ES/UL

  • FX2N Series FX2N-80MT

  • The arithmetic and control system : Stored program repeat operation method (dedicated LSI), there interrupt instruction

  • Input and output control method : Batch processing method (END when the instruction is executed), input and output refresh command, Pulse catch function

  • Programming language : Relay symbol system + step ladder system (SFC representation Allowed)

  • Program memory : The maximum memory capacity : 16000 step  comment, 16000 steps, including the file register

  • Built-in memory capacity and format : 8000 step RAM (backed up by a built-in lithium battery)

  • Memory cassette (memory board) : · FX-RAM-8 (2000/4000/8000/16000 step correspondence possible)  · FX-EPROM-8 (2000/4000/8000/16000 step correspondence possible)  · FX-EEPROM-4 (2000/4000 step correspondence possible)  · FX-EEPROM-8 (2000/4000/8000 step correspondence possible)  · FX-EEPROM-16 (2000/4000/8000/16000 step correspondence possible)

  • Function Expansion Memory (function expansion memory board) : The sequencer version V3.00 or higher, FX2N-ROM-E1 form function expansion memory board can be mounted  short-mail transmission function  inverter operation control function  -16000 step EEPROM (2000/4000/8000 step also correspondence possible)

  • RUN during the write function : Yes (can change programs during the sequencer RUN)

  • Protective function : There is password protection function (by keyword function)

  • Real-time clock : Clock function : Built  from 1980 to 2079 years (with leap year correction) The year 2-digit / 4-digit switch, monthly deviation ± 45 seconds (25 °C)

  • Type of instruction : Basic instruction : Sequence Instruction: 27  -step ladder instructions: two

  • Application Instructions : Application Instructions: 132 species

  • Arithmetic processing speed : Basic instruction : 0.08 s / instruction

  • Application Instructions : 1.52 to the number of 100 s / instruction

  • Input and output points : Number of inputs : 184 points or less (at the time of expansion in combination)

  • Number of outputs : 184 points or less (at the time of expansion in combination)

  • Remote I / O points (CC-Link) : Following the actual I / O, including 256 points

  • Total score : Less than 256 points (at the time of expansion in combination)

  • device : Input and output relay : Input relay : X000 ~ X267 184 points (octal number) extension when used with

  • Output relay : Y000 ~ Y267 184 points (octal number) extension when used with

  • Auxiliary relay : For general use : M0 ~ M499 500 points  is a non-battery backup area. You can change the battery backup area by the parameter setting.

  • For Keep : M500 ~ M1023 524 points  is a battery back-up area. You can change to a non-battery backup area by the parameter setting.

  • For Keep (battery backup fixed area) : M1024 ~ M3071 2048 points  is the battery backup fixed area. This area is characteristic not be changed.

  • For special : M8000 ~ M8255 256 points

  • State : Initial state : S0 ~ S9 10 points

  • For general use : S10 ~ S499 490 points  is a non-battery backup area. You can change the battery backup area by the parameter setting.

  • For Keep : S500 ~ S899 400 points  is a battery back-up area. You can change to a non-battery backup area by the parameter setting.

  • For annunciator : S900 ~ S999 100 points  is a battery back-up area. You can change to a non-battery backup area by the parameter setting.

  • Timer (on-delay) : 100ms : T0 ~ T199 200 points (0.1 to 3,276.7 seconds)

  • 10ms : T200 ~ T245 46-point (0.01 to 327.67 seconds)

  • 1ms integration type (capacitor keep) : T246 ~ T249 4 points (0.001 to 32.767 seconds)  is a battery-backed fixed area. This area is characteristic not be changed.

  • 100ms integration type (capacitor keep) : T250 ~ T255 6 points (0.1 to 3,276.7 seconds)  is a battery-backed fixed area. This area is characteristic not be changed.

  • counter : 16-bit up : C0 ~ C99 100 points (0 to 32,767 counts)  is a non-battery backup area. You can change the battery backup area by the parameter setting.

  • 16-bit up (battery backup area) : C100 ~ C199 100 points (0 to 32,767 counts)  is a battery back-up area. You can change to a non-battery backup area by the parameter setting.

  • 32-bit bi-directional : C200 ~ C219 20 points (-2,147,483,648 ~ + 2,147,483,647 count)  is a non-battery backup area. You can change the battery backup area by the parameter setting.

  • 32-bit bi-directional (battery backup area) : C220 ~ C234 15 points (-2,147,483,648 ~ + 2,147,483,647 count)  is a battery back-up area. You can change to a non-battery backup area by the parameter setting.

  • High-speed counter : [32-bit high-speed up / down]  C235 ~ C255 maximum six points usable in  one phase: 60KHz, 10KHz  2 phase: 30kHz, 5kHz  There is a limit to the number and input frequency that can be used by the conditions used.  It is a battery backup area. You can change to a non-battery backup area by the parameter setting.

  • Data register (32-bit in the pair used) : 16-bit general purpose : D0 ~ D199 200 points  is a non-battery backup area. You can change the battery backup area by the parameter setting.

  • 16 bit for Keep (battery backup area) : D200 ~ D511 312 points  is a battery back-up area. You can change to a non-battery backup area by the parameter setting.

  • 16 bit for Keep (battery backup fixed area) : D512 ~ D7999 7488 points (D1000 later, Allowed set to file register in the 500-point unit)  is a battery backup fixed area. This area is characteristic not be changed.

  • 16 bit for special : D8000 ~ D8255 256 points

  • For 16-bit index : V0 ~ V7, Z0 ~ Z7 16 points

  • Pointer : JUMP, for CALL branch : P0 ~ P127 128 points (CJ instruction, for the CALL instruction, for the END jump P63)

  • Input interrupt : I00 ~ I50 6 points

  • Timer interrupt : I6 ~ I8 3 points

  • Counter interrupt : I010 ~ I060 6 points (for HSCS instruction)

  • nesting : [Master control]  N0 ~ N7 8 points (for MC instruction)

  • constant : Decimal number (K) : 16-bit: -32,768 + 32,767  32-bit: -2,147,483,648 ~ + 2,147,483,647

  • Hexadecimal (H) : 16-bit: 0 ~ FFFF  32 bit: 0 ~ FFFFFFFF

  • Power Specifications :  

  • Rated voltage : AC100 ~ 240V

  • Allowable voltage range : AC85 ~ 264V

  • Rated frequency : 50 / 60Hz

  • Allowable momentary power failure time : 10ms will continue to operate for the momentary power failure follows.  If the power supply voltage is AC200V system, by the user program, you can change it to 10 ~ 100ms.

  • Power Fuse : 250V 5A

  • Inrush current : Maximum 40A 5ms or less / AC100V, maximum 60A 5ms or less / AC200V

  • Power consumption : 45W

  • DC24V service power : 460mA or less

  • DC5V internal supply power supply : 290mA

  • Input Specifications :  

  • Number of inputs : 40 points

  • Input connection shape : Removable terminal block (M3 screws)

  • Input format : sink

  • Input signal voltage : DC24V ± 10%

  • Input impedance : X000 ~ X007 : 3.3k

  • X010 or later : 4.3k

  • Input signal current : X000 ~ X007 : 7mA / DC24V

  • X010 or later : 5mA / DC24V

  • Input ON sensitivity current : X000 ~ X007 : More than 4.5mA

  • X010 or later : More than 3.5mA

  • Input OFF sensitivity current : 1.5mA or less

  • Input response time : About 10Ms  X000 ~ X017 (to basic unit built-in number) it has a built-in digital filter, can be changed in 1ms unit to 0 ~ 60ms depending on the application instructions or D8020.  If 0 is specified, X000, X001 is 20 s, X002 ~ X017 will be 50 s.

  • Input signal format : No-voltage contact input  NPN open collector transistor

  • Input circuit insulation : Photocoupler

  • Input Operation Display : Input ON when the LED lights up

  • Output Specifications :  

  • Number of outputs : 40 points

  • Output connection shape : Removable terminal block (M3 screws)

  • Output type / format : Transistor / sink output

  • External power supply : DC5 ~ 30V

  • Peak load : Resistance load : Output 1 point / common: 0.5A or less  output 4 points / common: 0.8A or less  Output 8 points / common: 1.6A or less  (Y000, Y001 is, 0.3A / output 1 point)

  • Inductive load : 12W / DC24V (Y000, Y001 is 7.2W / DC24V)

  • Minimum load : -

  • Open circuit leakage current : 0.1mA / DC30V

  • ON voltage : 1.5V

  • Response time : OFF ON : Y000, Y001: 15 s following  Y002 later: 0.2ms or less

  • ON OFF : Y000, Y001: 30 s following  Y002 later: 0.2ms or less

  • Circuit insulation : Photocoupler

  • Output operation display : Photocoupler drive when LED lighting

  • Built-in high-speed counter function :  

  • 1 phase 1 count input : [C235, C236]  up to two points: the best 60kHz  high speed compared to SET / RESET when using: 10kHz  high-speed bandwidth comparing HSZ use at the time: 5.5KHz  [C237 ~ C245]  up to 4 points: up to 10kHz  high speed compared to SET / RESET when using: 10kHz  high speed bandwidth comparing HSZ use at the time: 5.5kHz  high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is a 20kHz maximum. During the high-speed comparison SET / RESET use, high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is the maximum 11kHz is.  High-speed counter, pulse output instruction, the sum of the frequency at which the sequencer processes a pulse density instruction (the two-phase counter summing up the 2 times the input frequency), 5.5kHz is the maximum.

  • 1-phase 2-count input : [C246]  up to one point: the best 60kHz  high speed compared to SET / RESET when using: 10kHz  high-speed bandwidth comparing HSZ use at the time: 5.5KHz  [C247 ~ C250]  up to two points: the best 10kHz  high speed compared to SET / RESET when using: 10kHz  high-speed bandwidth comparing HSZ use at the time: 5.5kHz  high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is a 20kHz maximum. During the high-speed comparison SET / RESET use, high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is the maximum 11kHz is.  High-speed counter, pulse output instruction, the sum of the frequency at which the sequencer processes a pulse density instruction (the two-phase counter summing up the 2 times the input frequency), 5.5kHz is the maximum.

  • 2-phase 2-count input : [C251]  up to one point: the best 30kHz  high speed compared to SET / RESET when using: 5kHz  high-speed bandwidth comparing HSZ use at the time: 4kHz  [C252 ~ C255]  up to two points: the best 5kHz  high speed compared to SET / RESET when using: 4kHz  high-speed bandwidth comparing HSZ when using: 4kHz  high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is a 20kHz maximum. During the high-speed comparison SET / RESET use, high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is the maximum 11kHz is.  High-speed counter, pulse output instruction, the sum of the frequency at which the sequencer processes a pulse density instruction (the two-phase counter summing up the 2 times the input frequency), 5.5kHz is the maximum.

  • Built-in pulse output and positioning function :  

  • Number of controlled axes : Independent 2-axis

  • Maximum frequency : 20kHz

  • Programming language : Sequence program

  • Corresponding basic unit : Transistor output type basic unit

  • Pulse output instruction : Pulse output (PLSY)  , acceleration and pulse output with speed (PLSR)  pulse output format: pulse train (the direction is controlled by the sequence)

  • Positioning instruction : · ABS current value read ([D] ABS)  corresponding with V3.00 or more

  • Ambient temperature : 0 ~ 55 °C ····· operation, -20 ~ 70 °C ····· during storage

  • Relative humidity : 35 ~ 85% RH (non-condensing) ..... operation

  • Vibration resistance : When the DIN rail mounting : Frequency: 10 ~ 57Hz : Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes)  criteria, according to IEC61131-2

  • Frequency: 57 ~ 150Hz : Acceleration: 4.9m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes)  criteria, according to IEC61131-2

  • Direct mounting at the time : Frequency: 10 ~ 57Hz : Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes)  criteria, according to IEC61131-2

  • Frequency: 57 ~ 150Hz : Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes)  criteria, according to IEC61131-2

  • Impact : 147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z 3 times each direction  criterion, according to IEC61131-2

  • Anti-noise : Noise voltage 1,000Vp-p, noise width 1 s, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator

  • Withstand voltage : When performing a withstand voltage test, please go between the ground terminal of each terminal and the basic unit at a voltage of below.  Power supply terminal (AC power) and between the ground terminal: AC1.5kV 1 minute  DC24V service power supply, and the input terminal (DC24V) and between the ground terminal: AC500V 1 minute  output terminal (transistor) and between the ground terminal: AC500V 1 minute

  • Insulation resistance : When performing the insulation resistance test, please go between the ground terminal of each terminal and the basic unit at a voltage of below.  Power supply terminal (AC power) and between the ground terminal: DC500V 5M more in insulation resistance tester  DC24V service power supply, and the input terminal (DC24V) and between the ground terminal: DC500V 5M more in insulation resistance tester  and the output terminal (transistor) ground terminal between: DC500V 5M more in insulation resistance tester

  • ground : Class D grounding (ground resistance: 100 or less) <common ground is not allowed with the high-voltage system>  ground, please dedicated ground or shared ground.

  • Use atmosphere : Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly

  • Advanced use : 2000m or less  can not be used in the pressurized environment to more than atmospheric pressure. There is a possibility of failure.

  • Shipping Weight : 2.2 Kg

[short_review]
[long_review]
Did you find this helpful?  [rev_helpful] of [rev_votes] Found Helpful
Reviewed by: (Verified Buyer)  from [user_city]. [user_email] on [review_date]
[rating]
There are no reviews for this product!

Reward Points

571 points will be rewarded to you when you buy this item.

Related Items

https://www.nexinstrument.com/assets/images/03122016Mitsubishi/thumbnail/23.png

Recently Viewed Items

Legal Disclaimer

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.