Estimated Lead Time : Usually ships in 1 - 10 working days.
Manufacturer : Mitsubishi Electric
FX2N-48ER-ES/UL
I / O expansion unit FX2N - 48ER - ES / UL
Application sequencer : FX1N, FX3G, FX2N, FX3U
mass : 0.85 kg
Rated voltage : AC 100 V to 240 V
Voltage tolerance range : AC 85V ~ 264V
Rated frequency : 50/60 Hz
Power supply fuse : 250 V 5 A
Inrush current : AC 100 V: maximum 40 A 5 ms or less tengah AC 200 V: maximum 60 A 5 ms or less
power consumption : 35W
24 VDC service power supply : 24 VDC 460 mA or less When tengah connecting input / output extension block, 24 VDC service power is consumed.
Number of input points : 24 points
Input connection shape : Removable terminal block (M3 screw)
Input format : Sink / source
Input signal voltage : DC 24 V ± 10%
Input impedance : 4.3 kO
Input signal current : 5 mA / 24 VDC
Input ON sensitivity current : 3.5 mA or more
Input OFF sensitivity current : 1.5 mA or less
Input response time : About 10 ms
Input signal format : Sink: no-voltage contact input or NPN open collector transistor tengah source: no-voltage contact input or PNP open collector transistor
Input circuit insulation : Photocoupler insulation
Input operation display : LED on the panel when input is ON
Number of output points : 24 points
Output connection shape : Removable terminal block (M3 screw)
Output type / format : relay
External power supply: DC tengah 30 V or less AC 240 V or less (When not compliant with CE, UL, cUL standard, AC 250 V or less)
Maximum load Resistive load: tengah Please set the total load current per 2A / 1 point common as follows. tengah · Output 4 points / common: 8 A or less tengah · Output 8 points / common: 8 A or less
Inductive load : 80VA
Minimum load : DC 5 V 2 mA (reference value)
Response time OFF ? ON : About 10 ms
ON ? OFF : About 10 ms
Circuit insulation : Mechanical insulation
Output operation indication : LED lit when relay coil is energized
Ambient temperature : 0 to 55 ° C. ··· Operating -25 to 75 ° C. ····· Save
Relative humidity : 5 to 95% RH (noncondensing) · · · · in operation
Anti-vibration when DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The tengah criteria are based on IEC 61131-2
Anti-vibration when DIN rail is installed Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (total of 80 minutes each) The tengah criterion is based on IEC 61131-2
Anti-vibration direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The tengah criteria are based on IEC 61131-2
Anti-vibration direct installation Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The tengah criteria are based on IEC 61131-2
Impact resistance : 147 m / s 2 , working time 11 ms, tengah criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2
Noise immunity: Noise voltage with 1,000 Vp-p, noise width 1 µs, rising 1 ns, with noise si
tor with period of 30 to 100 Hz
Withstand voltage : Between the power supply terminal (AC power supply) and the earth terminal: AC 1500 V for 1 minute tengah 24 VDC Service power supply and between the input terminal (24 VDC) and the earth terminal: 500 tengah V AC for 1 minute Between the output terminal (relay)
Insulation resistance : Between each terminal and earth terminal: 500 MV DC 500 MO or more with an insulation resistance meter
ground : Class D grounding (grounding resistance: 100 O or less) tengah Grounding should be dedicated ground or common ground.
Use atmosphere: There is no corrosive property, flammable gas, conductive dust (dust) is not serious
Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
Shipping Weight : 2 Kg