Manufacturer: Mitsubishi Electric
FX2N-32MT-ES/UL
The arithmetic and control system : Stored program repeat operation method (dedicated LSI), there interrupt instruction
Input and output control method : Batch processing method (END when the instruction is executed), input and output refresh command, Pulse catch function
Programming language : Relay symbol system + step ladder system (SFC representation Allowed)
Program memory : The maximum memory capacity : 16000 step comment, 16000 steps, including the file register
Built-in memory capacity and format : 8000 step RAM (backed up by a built-in lithium battery)
Memory cassette (memory board) : Ā· FX-RAM-8 (2000/4000/8000/16000 step correspondence possible) Ā· FX-EPROM-8 (2000/4000/8000/16000 step correspondence possible) Ā· FX-EEPROM-4 (2000/4000 step correspondence possible) Ā· FX-EEPROM-8 (2000/4000/8000 step correspondence possible) Ā· FX-EEPROM-16 (2000/4000/8000/16000 step correspondence possible)
Function Expansion Memory (function expansion memory board) : The sequencer version V3.00 or higher, FX2N-ROM-E1 form function expansion memory board can be mounted short-mail transmission function inverter operation control function -16000 step EEPROM (2000/4000/8000 step also correspondence possible)
RUN during the write function : Yes (can change programs during the sequencer RUN)
Protective function : There is password protection function (by keyword function)
Real-time clock : Clock function : Built from 1980 to 2079 years (with leap year correction) The year 2-digit / 4-digit switch, monthly deviation ± 45 seconds (25 °C)
Type of instruction : Basic instruction : Sequence Instruction: 27 -step ladder instructions: two
Application Instructions : Application Instructions: 132 species
Arithmetic processing speed : Basic instruction : 0.08 s / instruction
Application Instructions : 1.52 to the number of 100 s / instruction
Input and output points : Number of inputs : 184 points or less (at the time of expansion in combination)
Number of outputs : 184 points or less (at the time of expansion in combination)
Remote I / O points (CC-Link) : Following the actual I / O, including 256 points
Total score : Less than 256 points (at the time of expansion in combination)
device : Input and output relay : Input relay : X000 ~ X267 184 points (octal number) extension when used with
Output relay : Y000 ~ Y267 184 points (octal number) extension when used with
Auxiliary relay : For general use : M0 ~ M499 500 points is a non-battery backup area. You can change the battery backup area by the parameter setting.
For Keep : M500 ~ M1023 524 points is a battery back-up area. You can change to a non-battery backup area by the parameter setting.
For Keep (battery backup fixed area) : M1024 ~ M3071 2048 points is the battery backup fixed area. This area is characteristic not be changed.
For special : M8000 ~ M8255 256 points
State : Initial state : S0 ~ S9 10 points
For general use : S10 ~ S499 490 points is a non-battery backup area. You can change the battery backup area by the parameter setting.
For Keep : S500 ~ S899 400 points is a battery back-up area. You can change to a non-battery backup area by the parameter setting.
For annunciator : S900 ~ S999 100 points is a battery back-up area. You can change to a non-battery backup area by the parameter setting.
Timer (on-delay) : 100ms : T0 ~ T199 200 points (0.1 to 3,276.7 seconds)
10ms : T200 ~ T245 46-point (0.01 to 327.67 seconds)
1ms integration type (capacitor keep) : T246 ~ T249 4 points (0.001 to 32.767 seconds) is a battery-backed fixed area. This area is characteristic not be changed.
100ms integration type (capacitor keep) : T250 ~ T255 6 points (0.1 to 3,276.7 seconds) is a battery-backed fixed area. This area is characteristic not be changed.
counter : 16-bit up : C0 ~ C99 100 points (0 to 32,767 counts) is a non-battery backup area. You can change the battery backup area by the parameter setting.
16-bit up (battery backup area) : C100 ~ C199 100 points (0 to 32,767 counts) is a battery back-up area. You can change to a non-battery backup area by the parameter setting.
32-bit bi-directional : C200 ~ C219 20 points (-2,147,483,648 ~ + 2,147,483,647 count) is a non-battery backup area. You can change the battery backup area by the parameter setting.
32-bit bi-directional (battery backup area) : C220 ~ C234 15 points (-2,147,483,648 ~ + 2,147,483,647 count) is a battery back-up area. You can change to a non-battery backup area by the parameter setting.
High-speed counter : [32-bit high-speed up / down] C235 ~ C255 maximum six points usable in one phase: 60KHz, 10KHz 2 phase: 30kHz, 5kHz There is a limit to the number and input frequency that can be used by the conditions used. It is a battery backup area. You can change to a non-battery backup area by the parameter setting.
Data register (32-bit in the pair used) : 16-bit general purpose : D0 ~ D199 200 points is a non-battery backup area. You can change the battery backup area by the parameter setting.
16 bit for Keep (battery backup area) : D200 ~ D511 312 points is a battery back-up area. You can change to a non-battery backup area by the parameter setting.
16 bit for Keep (battery backup fixed area) : D512 ~ D7999 7488 points (D1000 later, Allowed set to file register in the 500-point unit) is a battery backup fixed area. This area is characteristic not be changed.
16 bit for special : D8000 ~ D8255 256 points
For 16-bit index : V0 ~ V7, Z0 ~ Z7 16 points
Pointer : JUMP, for CALL branch : P0 ~ P127 128 points (CJ instruction, for the CALL instruction, for the END jump P63)
Input interrupt : I00 ~ I50 6 points
Timer interrupt : I6 ~ I8 3 points
Counter interrupt : I010 ~ I060 6 points (for HSCS instruction)
nesting : [Master control] N0 ~ N7 8 points (for MC instruction)
constant : Decimal number (K) : 16-bit: -32,768 + 32,767 32-bit: -2,147,483,648 ~ + 2,147,483,647
Hexadecimal (H) : 16-bit: 0 ~ FFFF 32 bit: 0 ~ FFFFFFFF
Power Specifications :
Rated voltage : AC100 ~ 240V
Allowable voltage range : AC85 ~ 264V
Rated frequency : 50 / 60Hz
Allowable momentary power failure time : 10ms will continue to operate for the momentary power failure follows. If the power supply voltage is AC200V system, by the user program, you can change it to 10 ~ 100ms.
Power Fuse : 250V 3.15A (3A)
Inrush current : Maximum 40A 5ms or less / AC100V, maximum 60A 5ms or less / AC200V
Power consumption : 30W
DC24V service power : 250mA or less
DC5V internal supply power supply : 290mA
Input Specifications :
Number of inputs : 16 points
Input connection shape : Removable terminal block (M3 screws)
Input format : sink
Input signal voltage : DC24V ± 10%
Input impedance : X000 ~ X007 : 3.3k
X010 or later : 4.3k
Input signal current : X000 ~ X007 : 7mA / DC24V
X010 or later : 5mA / DC24V
Input ON sensitivity current : X000 ~ X007 : More than 4.5mA
X010 or later : More than 3.5mA
Input OFF sensitivity current : 1.5mA or less
Input response time : About 10Ms X000 ~ X017 (to basic unit built-in number) it has a built-in digital filter, can be changed in 1ms unit to 0 ~ 60ms depending on the application instructions or D8020. If 0 is specified, X000, X001 is 20 s, X002 ~ X017 will be 50 s.
Input signal format : No-voltage contact input NPN open collector transistor
Input circuit insulation : Photocoupler
Input Operation Display : Input ON when the LED lights up
Output Specifications :
Number of outputs : 16 points
Output connection shape : Removable terminal block (M3 screws)
Output type / format : Transistor / sink output
External power supply : DC5 ~ 30V
Peak load : Resistance load : Output 1 point / common: 0.5A or less output 4 points / common: 0.8A or less Output 8 points / common: 1.6A or less (Y000, Y001 is, 0.3A / output 1 point)
Inductive load : 12W / DC24V (Y000, Y001 is 7.2W / DC24V)
Minimum load : -
Open circuit leakage current : 0.1mA / DC30V
ON voltage : 1.5V
Response time : OFF ON : Y000, Y001: 15 s following Y002 later: 0.2ms or less
ON OFF : Y000, Y001: 30 s following Y002 later: 0.2ms or less
Circuit insulation : Photocoupler
Output operation display : Photocoupler drive when LED lighting
Built-in high-speed counter function :
1 phase 1 count input : [C235, C236] up to two points: the best 60kHz high speed compared to SET / RESET when using: 10kHz high-speed bandwidth comparing HSZ use at the time: 5.5KHz [C237 ~ C245] up to 4 points: up to 10kHz high speed compared to SET / RESET when using: 10kHz high speed bandwidth comparing HSZ use at the time: 5.5kHz high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is a 20kHz maximum. During the high-speed comparison SET / RESET use, high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is the maximum 11kHz is. High-speed counter, pulse output instruction, the sum of the frequency at which the sequencer processes a pulse density instruction (the two-phase counter summing up the 2 times the input frequency), 5.5kHz is the maximum.
1-phase 2-count input : [C246] up to one point: the best 60kHz high speed compared to SET / RESET when using: 10kHz high-speed bandwidth comparing HSZ use at the time: 5.5KHz [C247 ~ C250] up to two points: the best 10kHz high speed compared to SET / RESET when using: 10kHz high-speed bandwidth comparing HSZ use at the time: 5.5kHz high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is a 20kHz maximum. During the high-speed comparison SET / RESET use, high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is the maximum 11kHz is. High-speed counter, pulse output instruction, the sum of the frequency at which the sequencer processes a pulse density instruction (the two-phase counter summing up the 2 times the input frequency), 5.5kHz is the maximum.
2-phase 2-count input : [C251] up to one point: the best 30kHz high speed compared to SET / RESET when using: 5kHz high-speed bandwidth comparing HSZ use at the time: 4kHz [C252 ~ C255] up to two points: the best 5kHz high speed compared to SET / RESET when using: 4kHz high-speed bandwidth comparing HSZ when using: 4kHz high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is a 20kHz maximum. During the high-speed comparison SET / RESET use, high-speed counter, pulse output instruction, the sum of the frequency at which the sequencer pulse density instruction processing (2-phase counter are totaled twice the input frequency) is the maximum 11kHz is. High-speed counter, pulse output instruction, the sum of the frequency at which the sequencer processes a pulse density instruction (the two-phase counter summing up the 2 times the input frequency), 5.5kHz is the maximum.
Built-in pulse output and positioning function :
Number of controlled axes : Independent 2-axis
Maximum frequency : 20kHz
Programming language : Sequence program
Corresponding basic unit : Transistor output type basic unit
Pulse output instruction : Pulse output (PLSY) , acceleration and pulse output with speed (PLSR) pulse output format: pulse train (the direction is controlled by the sequence)
Positioning instruction : Ā· ABS current value read ([D] ABS) corresponding with V3.00 or more
Ambient temperature 0 ~ 55 °C ····· operation, -20 ~ 70 °C ····· during storage
Relative humidity 35 ~ 85% RH (non-condensing) ..... operation
Vibration resistance When the DIN rail mounting Frequency: 10 ~ 57Hz Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes) criteria, according to IEC61131-2
Frequency: 57 ~ 150Hz Acceleration: 4.9M / S 2 X, Y, Z each direction 10 times (for a total of each 80 minutes) criteria, according to IEC61131-2
Direct mounting at the time Frequency: 10 ~ 57Hz Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes) criteria, according to IEC61131-2
Frequency: 57 ~ 150Hz Acceleration: 9.8M / S 2 X, Y, Z each direction 10 times (for a total of each 80 minutes) criteria, according to IEC61131-2
Impact 147M / S 2 , action time 11ms, X at half-sine pulse, Y, Z 3 times each direction criterion, according to IEC61131-2
Anti-noise Noise voltage 1,000Vp-p, noise width 1 s, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator
Withstand voltage When performing a withstand voltage test, please go between the ground terminal of each terminal and the basic unit at a voltage of below. Power supply terminal (AC power) and between the ground terminal: AC1.5kV 1 minute DC24V service power supply, and the input terminal (DC24V) and between the ground terminal: AC500V 1 minute output terminal (transistor) and between the ground terminal: AC500V 1 minute
Insulation resistance When performing the insulation resistance test, please go between the ground terminal of each terminal and the basic unit at a voltage of below. Power supply terminal (AC power) and between the ground terminal: DC500V 5M more in insulation resistance tester DC24V service power supply, and the input terminal (DC24V) and between the ground terminal: DC500V 5M more in insulation resistance tester and the output terminal (transistor) ground terminal between: DC500V 5M more in insulation resistance tester
ground Class D grounding (ground resistance: 100 or less) <common ground is not allowed with the high-voltage system> ground, please dedicated ground or shared ground.
Use atmosphere Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly
Advanced use 2000m or less can not be used in the pressurized environment to more than atmospheric pressure.There is a possibility of failure.
Shipping Weight: 1.65 Kg