Pulse output block FX 2 N - 10 PG

Pulse output block FX 2 N - 10 PG

 | 
Your Price: $357.00
Retail Price:$411.00
Your Savings:$54.00(13%)
Estimated Lead Time : In stock. Usually ships in 7-10 working days.
Part Number:FX2N-10PG

Condition : Brand New

Warranty : 12 months 

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • FX2N-10PG

  • Pulse output block FX 2 N - 10 PG

  • Number of control axes : Independent single axis

  • Pulse output method : Differential line driver system

  • Pulse output form : Pulse train + direction, forward rotation / reverse rotation pulse train

  • Maximum frequency : 1 MHz

  • Acceleration / deceleration processing : Automatic trapezoidal acceleration / deceleration, approximate S-shaped acceleration / deceleration

  • Control unit : pulse, μm, 10 -4 inch, mdeg

  • Positioning range : -2, 147, 483, 648 to +2, 147, 483, 647 pulse -2, 147, 483, 648 to +2, 147, 483, 647 [X (position data magnification) μm] -2, 147, 483, 648 to +2, 147, 483, 647 [X (position data magnification) X 10 -4 inch] -2, 147, 483, 648 to +2, 147, 483, 647 [X (position data magnification) mdeg] The position data magnification can be set to X 1, X 10, X 10 2, or X 10 3 in the parameter. It can be set in the range of -2, 147, 483, 648 to +2, 147, 483, 647 in terms of pulse conversion value.

  • Programming language : BFM can be specified directly by sequence program (FROM / TO instruction, application instruction operand)

  • Position data : 1 point (set with sequence program) 200 point (table) can be set when table positioning operation is performed.

  • Manual pulsar connection : Connectable (differential line driver, open collector)

  • Absolute position detection (ABS current value reading) : Use sequencer's ABS command

  • Number of occupied I / O points : Sequencer input / output 8 points occupation (It can count either input or output)

  • Application sequencer : FX2N, FX3U, FX2NC, FX3UCFX2NC - CNV - IF is required for connection to FX2NC. To connect to FX3UC, FX2NC - CNV - IF or FX3UC - 1PS - 5V is required.

  • mass : 0.2 Kg

  • Power-supply voltage : DC 5 V 120 mA (Internal power supply from PLC)

  • Input specification :

  • Control input : Control input: 3 points (START, DOG, PG 0) Interrupt input: 2 points (X0, X1) 2 phase pulser input: 1 point (φA, φB)

  • Input signal voltage START, DOG, X0, X1 : DC 24 V ± 10%

  • φ A, φ B : DC 3.0 V to 5.5 V

  • PG 0 : DC 3.0 V to 5.5 V

  • Input signal format START, DOG, X0, X1 : Contact or open collector transistor

  • φ A, φ B : Differential line driver or open collector transistor

  • PG 0 : Differential line driver or open collector transistor

  • Input signal current START, DOG, X0, X1 : 6.5 mA ± 1 mA

  • φ A, φ B : 6 mA to 20 mA

  • PG 0 : 6 mA to 20 mA

  • Input ON sensitivity START, DOG, X0, X1 : 4.5 mA or more

  • φ A, φ B : 6 mA or more

  • PG 0 : 6 mA or more

  • Input OFF sensitivity START, DOG, X0, X1 : 1.5 mA or less

  • φ A, φ B : 1 mA or less

  • PG 0 : 1 mA or less

  • Input capture speed START, DOG, X0, X1 : 0.1 ms or less (DOG is 1.0 ms or less)

  • φ A, φ B : 2 phase pulse 30 kHz or less (Duty 50%)

  • PG 0 : Pulse width 50 μs or more

  • Circuit insulation : Photocoupler insulation

  • Input operation display : LED ON when input is ON

  • Number of output points : 3 points (FP, RP, CLR)

  • Output form Pulse output unit (FP / RP) : You can select forward rotation (FP) / reverse rotation (RP) or pulse (PLS) / direction (DIR).

  • Clear signal (CLR) : It turns ON when homing operation is completed. (Output pulse width: 20 ms)

  • Output method Pulse output unit (FP / RP) : Differential line driver output

  • Clear signal (CLR) : NPN open collector transistor output

  • Rated load voltage Pulse output unit (FP / RP) : DC 5 V to 24 V (power supplied from the VIN terminal)

  • Clear signal (CLR) : DC 5V to 24V

  • Maximum load current Pulse output unit (FP / RP) : 25 mA or less

  • Clear signal (CLR) : 20 mA or less

  • VIN consumption current Pulse output unit (FP / RP) : At 24 VDC: 70 mA at 5 VDC : 100 mA

  • Maximum voltage drop during ON Clear signal (CLR) : 1.5V or less

  • Leakage current when OFF Clear signal (CLR) : 0.1 mA or less

  • Output frequency : 1 MHz

  • Output operation indication : LED on when output is ON

  • Ambient temperature : 0 to 55 ° C. ... Operating, -25 to 75 ° C. ..... Save

  • Relative humidity : 5 to 95% RH (noncondensing).... in operation

  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)

  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)

  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)

  • Impact resistance : 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse

  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si

  • tor with period of 30 to 100 Hz

  • Withstand voltage : Between external terminals and ground terminal of PLC main unit: AC 500 V for 1 minute

  • Insulation resistance : Between the external terminals collectively and the ground terminal of the programmable controller main body: 500 MV DC insulation resistance meter 5 MΩ or more

  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious

  • Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.

  • Shipping Weight : 1.2 Kg

Reward Points

Edit

357 points will be rewarded to you when you buy this item.

Related Items

 

Recently Viewed Items