FR-D720-1.5K | Mitsubishi Electric | Small inverters FREQROL-D 700 series Three-phase 200V
FR-D720-1.5K | Mitsubishi Electric | Small inverters FREQROL-D 700 series Three-phase 200V

FR-D720-1.5K | Mitsubishi Electric | Small inverters FREQROL-D 700 series Three-phase 200V

0 Review(s)
USD317.00
Retail Price:USD364.00
Your Savings:USD47.00(13%)
Availability: Estimated Lead Time : Usually ships in 1 - 10 working days.
Part Number: FR-D720-1.5K
Manufacturer:Mitsubishi Electric
Condition : Brand New
Warranty : 12 months 
Write a Review

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com.All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

NII REF No : IAAH110511041122

  • Estimated Lead Time : Usually ships in 1-10 working days.

  • Manufacturer : Mitsubishi Electric

  • Product no : FR-D720-1.5K

  • Product series : FREQROL-D 700

  • type : Easy · Small inverters FREQROL-D 700 series Three-phase 200V

  • Product model name : FR - D 720 - 1.5 K

  • Applicable motor capacity (kW) : 1.5 kW

  • Output Rated capacity (kVA) : 2.8

  • Output Rated current (A) : 7

  • Output Overload current rating : 150% 60 s, 200% 0.5 s (at inverse time characteristic)

  • Output Voltage : 3 phase 200 ~ 240V

  • Output Regenerative braking torque Maximum value · Allowable usage rate : -

  • Power supply Voltage class : Three-phase 200V class

  • Power supply Rated input AC voltage · Frequency : 3 phase 200 ~ 240 V 50 Hz / 60 Hz

  • Power supply AC voltage allowable variation : 170 to 264 V 50 Hz / 60 Hz

  • Power supply Frequency tolerance variation : ± 5%

  • Power supply equipment capacity (kVA) : Four

  • Protective structure (JEM 1030) : Closed type (IP 20), fully closed structure series is IP 40.

  • cooling method : Forced air cooling

  • Approximate mass (kg) : 1.4

  • control method : Soft-PWM control / high carrier frequency PWM control (V / F control, general magnetic flux vector control, optimum excitation control can be selected)

  • Control specification-Output frequency range : 0.2 to 400 Hz

  • Control specification-Frequency setting resolution-Analog input : 0.06 Hz / 60 Hz (Terminal 4: 0 to 20 mA / 10 bits), 0.06 Hz / 60 Hz (Terminals 2, 4: 0 to 10 V / 10 bits), 0.12 Hz / 60 Hz (Terminals 2 and 4: 0 to 5 V /

  • Control specification-Frequency setting resolution-Digital input : 0.01 Hz

  • Control specification-Frequency accuracy-Analog input : Within ± 1% of maximum output frequency (25 ° C ± 10 ° C)

  • Control specification-Frequency accuracy-Digital input : Within 0.01% of setting output frequency

  • Control specification-Voltage / frequency characteristics : Base frequency 0 to 400 Hz Optional setting, constant torque · reduction Torque pattern selectable

  • Control specification-Starting torque : 150% or more (at 1 Hz) · · · When slip correction is set by general-purpose magnetic flux vector control

  • Control specification-Torque boost : Manual torque boost

  • Control specification-Acceleration / deceleration time setting : 0.1 ~ 3600 s (Individual acceleration / deceleration setting possible), linear or S-shaped acceleration / deceleration mode selectable

  • Control specification-DC braking : Operating frequency (0 to 120 Hz), operating time (0 to 10 s), operating voltage (0 to 30%) variable

  • Control specification-Stall prevention operation level : Operating current level selectable (0 to 200% variable), selectable

  • Control specification-Torque limit level : None

  • Driving function : Upper / lower limit frequency setting, frequency jump operation, external thermal input selection, instantaneous power failure restart operation, forward / reverse rotation prevention, remote setting, second function, multi-speed operation, regeneration avoidance, slip correction, operation mode selection, offline auto tuning Function, PID control, Computer link operation (RS - 485), Optimum excitation control, Power outage stop, Speed ??smoothing control, Modbus - RTU

  • Frequency setting signal-Number of analog input terminals : 2 points

  • Frequency setting signal-Analog input terminal specification : Terminal 2: 0 to 10 V, 0 to 5 V selectable, terminal 4: 0 to 10 V, 0 to 5 V, 4 to 20 mA selectable

  • Frequency setting signal-Digital input : Input by operation panel, parameter unit, frequency setting unit selectable

  • Start signal : Individual normal rotation / reverse rotation, start signal self-holding input (3 wire input) selectable

  • input signal-Number of terminal points (contact input) : 5 points

  • input signal-Pulse train input : None

  • input signal-Input terminal selectable signal : External thermal input, PU - external operation switching, V / F switching, output stop, start self-holding selection, positive terminal selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal Pr. 178 to Pr. 182 (input terminal function selection) arbitrary signal from the external interlock of the PU operation, PU operation, PU operation, changeover command, inverter reset, PUNET operation changeover, external-NET operation changeover, Select by

  • Operating specification-Output signal-Output terminal (open collector output) Number of points : 1point

  • Operating specification-Output signal-Number of output terminals (relay output) : 1point

  • Operating specification-Output signal-Output terminal selectable signal : During inverter operation, frequency reached, overload alarm, output frequency detection, regenerative brake pre alarm, electronic thermal pre alarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward rotation Safety monitor output, Safety monitor output 2, Retrying, Lifetime alarm, Current average value monitor, Remote output, Minor fault output , Abnormal output, abnormal output 3, maintenance timer alarm, selected by Pr. 190, Pr. 192, Pr. 197 (output terminal function selection).

  • Operating specification-Output signal-Output terminal selectable signal (when option is installed) : Can not install built-in option

  • Operating specification-Output signal-Number of display terminal output terminals : 1point

  • Operating specification-Output signal-Display meter output terminal specification : FM: Up to 2.4 kHz

  • Operating specification-Output signal-Pulse train output : None

  • Operating specification-Output signal-Display meter output terminal selectable signal : Output frequency, Output current (steady state), Output voltage, Frequency setting value, Converter output voltage, Regenerative brake usage rate, Electronic thermal load factor, Output current peak value, Converter output voltage peak value, Reference voltage output, Motor load factor, PID Select the target value, PID measurement value, output power, PID deviation, motor thermal load factor, inverter thermal load factor by Pr.54 FM terminal function selection, pulse train output (1440 pulses / s / full scale)

  • display-control panel-Operating condition : Output frequency, Output current (steady state), Output voltage, Frequency set value, Integrated energization time, Actual operating time, Converter output voltage, Regenerative brake usage rate, Electronic thermal load factor, Output current peak value, Converter output voltage peak value, Motor Selectable from load factor, PID target value, PID measurement value, PID deviation, inverter input / output terminal monitor, output power, integrated power, motor thermal load factor, inverter thermal load factor, PTC thermistor resistance value

  • display-control panel-Abnormal content : Abnormality content is displayed during operation of protection function, 8 times of abnormality content is memorized (output voltage, current, frequency, total energization time immediately before protection function operation)

  • Protection / alarm function : <Protection function> Overcurrent during acceleration, overcurrent during deceleration, overcurrent during deceleration, overvoltage during acceleration, overvoltage during constant speed, deceleration Overvoltage, inverter protection thermal operation, motor protection thermal operation, fin overheating, At startup Output side ground fault current, output phase loss, external thermal operation, PTC thermistor operation, parameter error, PU missing occurrence, over retry count, CPU abnormality, brake transistor abnormality, inrush resistance overheat, analog input abnormality, stop due to stall prevention , the output current detection value over, safety circuit abnormality <alarm function> fan fault, overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter write error, regenerative brake prealarm, electronic thermal pre-alarm, maintenance output, undervoltage, operation Panel lock, Password setting, Inverter resetting, Safety Stopped

  • Ambient temperature environment : -10 ° C to + 50 ° C (no freezing) (-10 ° C to + 40 ° C when fully closed structure specifications)

  • Ambient humidity environment : 90% RH or less (no condensation)

  • storage temperature environment : -20 ° C to + 65 ° C

  • atmosphere environment : Indoor (no corrosive gas, flammable gas, oil mist, dust)

  • Altitude / vibration environment : Sea level 1000 m or less · 5.9 m / s 2 or less

  • communication : RS-485, Modbus RTU

  • Shipping Weight : 2.4 Kg

Reward Points

317 points will be rewarded to you when you buy this item.

Related Items

Recently Viewed Items

The cookie settings on this website are set to 'allow all cookies' to give you the very best experience. Please click Accept Cookies to continue to use the site.