Estimated Lead Time : 4-6 Weeks
-
Manufacturer : SICK Sensors
-
Bar code scanners CLV64x / Standard Density
-
Type : CLV640-6000
-
Part number : 1042022
-
Version : Standard Density
-
Connection type : Cable
-
Reading field : Oscillating mirror
-
Scanner design : Line scanner
-
Focus : Dynamic focus control
-
Light source : Visible red light (655 nm)
-
Light spot : Circular
-
MTBF : 40,000 h
-
Laser class : 2 (IEC 60825-1:2014, EN 60825-1:2014)
-
Aperture angle : = 50°
-
Scanning frequency : 400 Hz...1,200 Hz
-
Code resolution : 0.2 mm...1 mm
-
Reading distance : 45 mm...755 mm 1)
-
Oscillating mirror functions : Fixed (adjustable position), oscillating (variable or fixed amplitude), one shot
-
Oscillation frequency : 0.5 Hz...6.25 Hz
-
Angle of deflection : –20°...20°
-
1) For details see reading field diagram.
-
PERFORMANCE :-
-
Bar code types : All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Telepen, MSI/Plessey
-
Print ratio : 2:1...3:1
-
No. of codes per scan : 1...20 (Standard decoder) : 1...6 (SMART decoder)
-
No. of codes per reading interval : 1...50 (auto-discriminating)
-
No. of characters per reading interval : 5,000 : 500 (for multiplexer function in CAN operation)
-
No. of multiple readings : 1...99
-
INTERFACES :-
-
PROFINET : Yes
-
Function : PROFINET Dual Port (optional via external connection module CDF600-2)
-
EtherCAT® : Yes
-
Type of fieldbus integration : Optional over external fieldbus module CDF600
-
Serial : Yes , RS-232, RS-422, RS-485
-
Function : Host, AUX
-
Data transmission rate : 2,400 Baud...115.2 kBaud, AUX: 57.6 kBaud (RS-232)
-
CAN : Yes
-
Function : SICK CAN sensor network CSN (master/slave, multiplexer/server)
-
Data transmission rate : 20 kbit/s...1 Mbit/s
-
CANopen : Yes
-
Data transmission rate : 20 kbit/s...1 Mbit/s
-
PROFIBUS DP : Yes
-
Type of fieldbus integration : Optional over external fieldbus module CDF600-2
-
DeviceNet™ Yes
-
Type of fieldbus integration Optional, over external connection module CDM + CMF
-
Switching inputs : 4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420)
-
Switching outputs : 4 (“Result 1”, “Result 2”, 2 outputs via optional parameter storage CMC600 in CDB620/CDM420)
-
Reading pulse : Switching inputs, non-powered, serial interface, auto pulse, CAN
-
Optical indicators : 6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs))
-
Acoustic indicators : Beeper/buzzer (can be switched off, can be allocated as a result indication function)
-
Operating elements : 2 buttons (choose and start/stop functions)
-
Configuration software : SOPAS ET
-
Memory card : MicroSD memory card (flash card), optional
-
MECHANICS/ELECTRONICS :-
-
Electrical connection : 1 x 15-pin D-Sub HD male connector (0.9 m)
-
Operating voltage : 18 V DC...30 V DC
-
Power consumption : 6.5 W
-
Housing : Aluminum die cast
-
Housing color : Light blue (RAL 5012)
-
Front screen : Glass
-
Enclosure rating : IP65 (EN 60529)
-
Protection class : III (EN 61140)
-
Weight : 420 g, with connecting cable
-
Dimensions (L x W x H) : 95 mm x 107 mm x 41 mm
-
AMBIENT DATA:-
-
Electromagnetic compatibility (EMC) : EN 61000-6-3 (2001-10) / EN 61000-6-2:2005
-
Vibration resistance : EN 60068-2-6 (1995)
-
Shock resistance : EN 60068-2-27 (1993)
-
Ambient operating temperature : 0 °C...+40 °C
-
Storage temperature : –20 °C...+70 °C
-
Permissible relative humidity : 90 %, Non-condensing
-
Ambient light immunity : 2,000 lx, on bar code
-
Bar code print contrast (PCS) : = 60 %
-
GENERAL NOTES :-
-
Note on use : For Ethernet connection please use an Ethernet version of CLV6xx
-
Shipping Weight : 1.4 Kg