CC-Link platinum resistance temperature detector Pt100 temperature input unit AJ65BT-64RD3

CC-Link platinum resistance temperature detector Pt100 temperature input unit AJ65BT-64RD3

Your Price: $605.00
Retail Price:$696.00
Your Savings:$91.00(13%)

Condition : Brand New

Warranty : 12 months 

Estimated Lead Time : In stock. Usually ships in 7-10 working days.
Part Number:AJ65BT-64RD3
You need to be a registered customer to order this product. Please Login to your account or click here to Register.

Sign in with Facebook
  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.

  • Manufacturer : Mitsubishi Electric

  • AJ65BT-64RD3

  • CC-Link platinum resistance temperature detector Pt100 temperature input unit AJ65BT-64RD3

  • Number of channels : 4 channels

  • Digital output Temperature measurement value : 16-bit signed binary (-1800 to 6000: value to the first decimal place X 10 times) 32-bit signed binary (-180000 to 600000: value up to the third decimal place X 1000 times)

  • Measuring method : 3 wire type

  • Usable resistance temperature detector : Pt 100, JPt 100

  • Measurement temperature range Pt 100 : -180 to 600 ° C

  • JPt 100 : -180 to 600 ° C

  • Output current for temperature detection : 1 mA

  • resolution : 0.025 °C

  • Overall accuracy (accuracy with respect to maximum value) Ambient temperature: 25 ± 5 ° C : ± 0.1%

  • Ambient temperature: 20 ° C or less, 30 ° C or more : ± 0.25%

  • Conversion speed : 40 ms / channel

  • Insulation method : Between platinum resistance temperature detector input and CC-Link transmission system: Photocoupler isolation Channel to non-insulation

  • Withstand voltage : Between power supply system batch and earth, power supply system batch and communication system batch, communication system batch and temperature input batch, between temperature input batch and ground: AC 500 V for 1 minute

  • Insulation resistance : Between power supply system batch and earth, power supply system batch and communication system batch, between communication system batch and temperature input batch, between temperature input batch and ground: 500 MV with insulation resistance meter 10 MΩ or more

  • Station type : Remote device station (Ver.1 remote device station)

  • Number of occupied stations : 4 stations

  • Unit power supply Voltage : DC 24 V (DC 18 to 30 V)

  • Current : 0.17 A

  • Allowable momentary power failure time : 1 ms

  • External wiring connection method : Communication unit, Unit power supply unit: 7 points 2-piece terminal block (M3.5 screw) I / O section: 27 points 2 piece terminal block (M3.5 screw)

  • communication cable : CC-Link dedicated cable

  • External dimensions Height (H) : 65 mm

  • Width (W) : 151.9 mm

  • Depth (D) : 63 mm

  • mass : 0.38 Kg

  • Operating ambient temperature : 0 to 55 ° C

  • Storage ambient temperature : -20 to 75 ° C

  • Ambient operating humidity : 10 to 90% RH, non condensing

  • Storage ambient humidity : 10 to 90% RH, non condensing

  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz , Amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions

  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, Amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Acceleration: 4.9 m / s 2

  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)

  • Use atmosphere : No corrosive gas

  • Use elevation : 0 to 2000 m

  • Installation location : In the control panel

  • Over voltage category : II or less

  • Pollution degree : 2 or less

  • Shipping Weight : 1.4 Kg

Related Items