Power supply unit - QUINT-PS/1AC/24DC/40 - 2866789

Power supply unit - QUINT-PS/1AC/24DC/40 - 2866789

Your Price: $550.00
Retail Price:$633.00
Your Savings:$83.00(13%)
Estimated Lead Time : 2-3 Weeks
Part Number:2866789

Condition : Brand New

Warranty : 12 months 

You need to be a registered customer to order this product. Please Login to your account or click here to Register.

Sign in with Facebook

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

  • Estimated Lead Time : 2-3 Weeks

  • Manufacturer : Phoenix Contact

  • Orderkey : 2866789

  • Packing unit : 1 pc

  • Catalog page : Page 210 (C-4-2017)

  • GTIN : 4046356421720

  • Weight per Piece (excluding packing) : 3,815.800 g

  • Custom tariff number : 85044030

  • Country of origin : TH (Thailand)

  • Width : 180 mm

  • Height : 130 mm

  • Depth : 125 mm

  • Width with alternative assembly : 122 mm

  • Height with alternative assembly : 130 mm

  • Depth with alternative assembly : 183 mm

  • Degree of protection : IP20

  • Ambient temperature (operation) : -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)

  • Ambient temperature (start-up type tested) : -40 °C

  • Ambient temperature (storage/transport) : -40 °C ... 85 °C

  • Max. permissible relative humidity (operation) : <= 95 % (at 25 °C, non-condensing)

  • Climatic class : 3K3 (in acc. with EN 60721)

  • Degree of pollution : 2

  • Installation height : 4000 m

  • Nominal input voltage range : 100 V AC ... 240 V AC
    : 120 V DC ... 300 V DC (UL 508 <= 250 V DC)

  • Input voltage range : 85 V AC ... 264 V AC
    90 V DC ... 300 V DC (UL 508: <= 250 V DC)

  • Dielectric strength maximum : 300 V AC

  • AC frequency range : 45 Hz ... 65 Hz

  • Frequency range DC : 0 Hz

  • Discharge current to PE : < 3.5 mA

  • Current consumption : 8.8 A (120 V AC)
    4.6 A (230 V AC)
    9.5 A (110 V DC)
    4.7 A (220 V DC)

  • Nominal power consumption : 1030 W

  • Inrush surge current : < 15 A (typical)

  • Mains buffering : > 35 ms (120 V AC)
    : > 35 ms (230 V AC)

  • Input fuse : 20 A (slow-blow, internal)

  • Choice of suitable circuit breakers : 16 A ... 20 A (AC: Characteristics B, C, D, K)

  • Type of protection : Transient surge protection

  • Protective circuit/component : Varistor, gas-filled surge arrester

  • Nominal output voltage : 24 V DC ±1 %

  • Setting range of the output voltage (USet) : 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)

  • Nominal output current (IN) : 40 A (-25 °C ... 60 °C, UOUT = 24 V DC)

  • POWER BOOST (IBoost) : 45 A (-25°C ... 40°C permanent, UOUT = 24 V DC )

  • Selective Fuse Breaking (ISFB) : 215 A (12 ms)

  • Derating : 60 °C ... 70 °C (2.5%/K)

  • Connection in parallel : Yes, for redundancy and increased capacity

  • Connection in series : yes

  • Feedback resistance : max. 35 V DC

  • Circuit breaker against surge voltage at output by invasive foreign matter : < 35 V DC

  • Residual ripple : < 30 mVPP (with nominal values)

  • Output power : 960 W

  • Typical response time : < 0.7 s

  • Maximum power dissipation in no-load condition : 14 W

  • Power loss nominal load max. : 80 W

  • Net weight : 3.3 kg

  • Efficiency : > 92 % (for 230 V AC and nominal values)

  • Insulation voltage input/output : 4 kV AC (type test)

  • : 2 kV AC (routine test)

  • Insulation voltage input / PE : 3.5 kV AC (type test)

  • : 2 kV AC (routine test)

  • Insulation voltage output / PE : 500 V DC (routine test)

  • Protection class : I

  • Degree of protection : IP20

  • MTBF (IEC 61709, SN 29500) : > 900000 h (25 °C)
    : > 530000 h (40 °C)

  • Mounting position : horizontal DIN rail NS 35, EN 60715

  • Assembly instructions : alignable: PN >=50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
    alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom

  • Connection method : Screw connection

  • Conductor cross section solid min. : 0.2 mm²

  • Conductor cross section solid max. : 6 mm²

  • Conductor cross section flexible min. : 0.2 mm²

  • Conductor cross section flexible max. : 4 mm²

  • Conductor cross section AWG min. : 14

  • Conductor cross section AWG max. : 10

  • Stripping length : 7 mm

  • Screw thread : M3

  • Connection method : Screw connection

  • Conductor cross section solid min. : 0.5 mm²

  • Conductor cross section solid max. : 16 mm²

  • Conductor cross section flexible min. : 0.5 mm²

  • Conductor cross section flexible max. : 16 mm²

  • Conductor cross section AWG min. : 8

  • Conductor cross section AWG max. : 6

  • Stripping length : 10 mm

  • Screw thread : M4

  • Conductor cross section solid min. : 0.2 mm²

  • Conductor cross section solid max. : 6 mm²

  • Conductor cross section flexible min. : 0.2 mm²

  • Conductor cross section flexible max. : 4 mm²

  • Conductor cross section AWG min. : 24

  • Conductor cross section AWG max. : 10

  • Screw thread : M3

  • Electromagnetic compatibility : Conformance with EMC Directive 2014/30/EU

  • Noise emission : EN 55011 (EN 55022)

  • Noise immunity : EN 61000-6-2:2005

  • Connection in acc. with standard : CSA

  • Standards/regulations : EN 61000-4-2

  • Contact discharge : 4 kV (Test Level 2)

  • Standards/regulations : EN 61000-4-3

  • Frequency range : 80 MHz ... 1 GHz

  • Test field strength : 10 V/m (Test Level 3)

  • Frequency range : 1.4 GHz ... 2 GHz

  • Test field strength : 3 V/m (Test Level 2)

  • Standards/regulations : EN 61000-4-4

  • Comments : Criterion B

  • Standards/regulations : EN 61000-4-5

  • Signal : 1 kV (Test Level 2 - asymmetrical)

  • Standards/regulations : EN 61000-6-3 | EN 61000-4-6

  • Frequency range : 0.15 MHz ... 80 MHz

  • Voltage : 10 V (Test Level 3)

  • Low Voltage Directive : Conformance with LV directive 2006/95/EC

  • Standard - Electrical safety : IEC 60950-1/VDE 0805 (SELV)

  • Standard-Electronic equipment for use in electrical power installations and their assembly into electrical power installations : EN 50178/VDE 0160 (PELV)

  • Standard-Safety extra-low voltage : IEC 60950-1 (SELV) and EN 60204-1 (PELV)

  • Standard - Safe isolation : DIN VDE 0100-410 | DIN VDE 0106-101

  • Standard-Protection against shock currents, basic requirements for protective separation in electrical equipment : EN 50178

  • Standard-Limitation of mains harmonic currents : EN 61000-3-2

  • Standard - Equipment safety : BG (design tested)

  • Standard - Approval for medical use : IEC 60601-1, 2 x MOOP

  • Shipbuilding approval : DNV GL (EMC A), ABS, LR, RINA, NK, BV

  • UL approvals : UL Listed UL 508 | UL/C-UL Recognized UL 60950-1 | UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)

  • Shock : 18 ms, 30g, in each space direction (according to IEC 60068-2-27)

  • Vibration (operation) : < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
    : 15 Hz ... 150 Hz, 2.3g, 90 min.

  • Information technology equipment - safety (CB scheme) : CB Scheme

  • Rail applications : EN 50121-4

  • Overvoltage category (EN 62477-1) : III

  • China RoHS : Environmentally Friendly Use Period = 25;

  • Shipping Weight : 5 Kg

Related Items