2104B2111 | Honeywell | Short Range Receiver ATEX Source

2104B2111 | Honeywell | Short Range Receiver ATEX Source

Your Price: $9,856.00
Retail Price:$11,334.00
Your Savings:$1,478.00(13%)
Estimated Lead Time : 6 - 8 weeks
Part Number:2104B2111

Condition : Brand New

Warranty : 12 months 

You need to be a registered customer to order this product. Please Login to your account or click here to Register.

Sign in with Facebook

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

  • Estimated Lead Time : 6 - 8 weeks

  • Manufacturer : Zellweger Analytics

  •  2104B2111

  • Spares Parts-Receiver Std Version Short Range ATEX

  • Available Gases : Methane, Ethane, Propane, Butane, Pentane, Ethylene, Propylene, Ethanol, Methanol.

  • Range : 0 to 5 LEL.m.

  • Recommended Alarm Settings : (Low) 1.0 LEL.m; (high) 3.0 LEL.m.

  • Path Lengths : Short Range 5 to 40m (15 to 130 ft.), Medium Range 40 to 120m (130 to 390ft.) and Long Range 120 to 200m (390 to 650ft.)

  • Speed of Response : T90 less than 3 seconds. (under normal operating conditions).

  • Output Signal : 4 to 20mA (maximum loop resistance 600 ohms; source & sink available) and RS485.
    21mA Over range.
    4 to 20mA Normal operation (0 to 5 LELm).
    3mA (1) Dirty optics.
    2.5mA (1) Beam blocked.
    2mA (1) Inhibit.
    0mA Fault.

  • Digital Output : Modbus RS485 multi drop. Using DVC100(m) or DX100(m).

  • Operating Temperature : -40 to +65°C (-40 to 150°F).

  • Operating Humidity : 0 to 99% RH (non-condensing).

  • Operating Pressure : 91.5 to 105.5 KPa (915 to 1055 mbar) (non-compensated).

  • Warm-up Time : Less than 5 minutes (operational), or less than 1 hour (fully stabilised).

  • Power Supply : 18V to 32V dc.

  • Power Consumption : Short Range TX: 3.5 / 5.0*W maximum. Medium and Long Range TX: 5.5 / 7.5*W maximum. RX: 8W maximum.

  • Enclosure Material : 316 stainless steel.

  • Weight (inc. mounting bracket) : Short Range TX: 3.5kg. Medium and Long Range TX: 7kg. RX: 3.5kg.

  • Vibration : 2 to 60Hz, max ptp amplitude 1mm.

  • Misalignment Tolerance : Short Range ±0.5o (±~35cm at 40m). Medium Range ±0.5a (±~104cm at 120m). Long Range ±0.5o (±~170cm @ 200m).

  • EMC Standards : EN50270:1999

  • Performance Approval : FM performance approved.

  • Safety Approval : ATEX: EExd IIC T5(-40°C to +65°C).
    EExd IIC T6(-40°C to +40°C).
    II 2G.
    UL: Class 1 Div 1 Groups B,C + D and Class 1 Zone 1 AEx d IIB + H2 (Tamb -40°C to +65°C).
    CSA: Class 1 Div 1 Groups B,C + D, T5 and Exd IIC T5 (Tamb -40°C to +65°C).
    FM: Class 1 Div 1 Groups B,C and D
    Other: SAA, GOSST.
    Independently assessed to IEC61508

  • I.P. Rating : IP66 and IP67.

  • Weight (inc. mounting bracket) Short Range TX: 3.5kg. Medium and Long Range TX: 7kg. RX: 3.5kg